Southbend R2 manual +-D- -c

Models: R2

1 21
Download 21 pages 29.24 Kb
Page 4
Image 4
+-D- -c

NOTE: Not for Scale. For Dimensional Purposes Only.

k-G-

+-D- -c

4 rc- MINIMUM CLEARANCE

FRONT VIEW

SIDE VIEW

F

TOP VIEW

 

 

 

%% Electric connection - terminal block

6& Drain 1 l/4” o.d., leave open, do not connect to floor drain

5 Cold water inlet l/4”, 30 p.s.i. min.-60 p.s.i. max.

DIMENSIONS:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(

) = Millimeters

 

 

Width

Height

 

DEPTH

DRAIN

 

 

WATER

/ ELECTCONN

/

 

CRATE SIZE

Cubic

Crated

MODEL

A

B

 

C

D

E

i

 

F

 

G

H

J

 

K

I

Width

1 Depth

1 Height

Volume

Weight

 

R2

-

24318”

28318”

8 l/2*

/

1 114”

14

318”

1 l/4”

4 314”

(2)

 

19 l/2”

’ 31 i/2-

28 l/2”

10.13cf

112::

 

 

$6,

(:;3)

 

(625)

(727)

(216)

!

(32)

(365)

(32)

(121)

 

(499)

/ (800)

1

(724)

.29 cm

51 kg

Internal Dimensions:

13 11’2W x 22 D x 12 l/2

H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UTILITY

INFORMATION:

ELECTRIC: One electric connection per unit is required.

 

 

 

 

 

 

 

 

 

 

SINGLE UNiT

 

 

MAX. AMPS

 

PER LINE

 

WATER USAGE AT TIMED OR MANUAL COOKING:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TOTAL

CONNECTED

AMPS

1 PHASE

/

3 PHASE

 

 

0.46

total gallons

per

minute

at 45

p.s.i.

 

 

 

 

 

208 V 60 Hz

 

 

 

 

44

I

 

25

 

 

IMPORTANT: UNIT

MUST

BE LEVEL FOR PROPER OPERATION.

 

220 V 50160 Hz

 

 

 

41

 

 

24

 

 

WARRANTY WILL BE VOIDED FOR IMPROPER INSTALLATION.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

240 V 60 Hz

 

 

 

 

38

 

 

22

 

 

“Ail

units shipped

per customer order, three

phase or single phase.

 

3BOl220 V 50 Hz

 

 

 

24

 

 

14

 

 

If necessary to change see installation section for conversion.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

4151240 V 50 Hz

 

 

I

22

I

 

13

 

I

 

 

 

 

 

 

 

 

 

 

 

1

480V60Hz

 

 

 

 

19

 

 

11

 

J

 

 

 

 

 

 

 

 

 

 

 

Circuit must be wired for maximum amps at required voltage.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

!

WATER

SPECIFICATIONS:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To meet warranty requirements, supply water must be as

 

 

 

 

 

 

 

 

 

 

 

 

 

follows:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Connection:

 

 

 

 

l/4”

cold

water

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pressure:

 

 

 

 

30 to 60 PSI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Total

Dissolved

Solids

TTDS):

 

60

PPM

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Hardness:

 

 

 

1 2 arainsor35

PPM

1

 

 

 

 

 

 

 

 

 

 

 

1

PH Factor:

 

 

 

I

7.0 to

7.5

 

I

 

 

 

 

 

 

 

 

 

 

 

PAGE 3

Page 4
Image 4