Convection-Oven Blower Does Not Run, Continued

SERVICE

500 SERIES RESTAURANT RANGES

Figure 12

Convection-Oven Blower Does Not Run, Continued

(Continuing from previous page.)

CHECK THAT POWER IS DISCONNECTED

AT CIRCUIT BREAKER.

Remove the wire terminal cover from the blower motor.

Check that the red wire is capped off.

Remove the wire nuts from the black and the white wires. Check

that in each case the wires are twisted together securely.

Check that the common wire is connected to the motor black wire.

Check that the neutral wire is connected to the white wire.

Reconnect the power supply and turn on blower-control switch. Use a voltmeter to measure the voltage between the black wire and the white wire.

No

Is there voltage?

Yes

 

 

 

DISCONNECT POWER AT CIRCUIT BREAKER.

Check all wiring for loose terminals or breaks.

DISCONNECT POWER AT CIRCUIT BREAKER.

Remove the wire nuts from the red, white, and black wires. Check that the resistance across the white and black wires is approximately 1.9 ohms. Check that the resistance across the white and red wires is also approximately 1.9 ohms. If either resistance is incorrect, replace the blower motor.

ADJUSTMENT OF GAS PRESSURE REGULATOR

The pressure regulator is factory set at 4" W.C. (0.99 kPa) for natural gas and 10" W.C. (2.48 kPa) for propane gas. To check the manifold pressure:

1.Turn all thermostats and burner valves to OFF position.

2.Turn main gas valve to entire range off.

3.Remove valve panels and locate the small plug in the manifold.

4.Remove plug and install a fitting appropriate to connect a manometer.

5.Turn on main gas to range and light pilots.

6.Turn all burners and ovens to full ON position and read manometer.

7.If manometer does not read 4" W.C. (0.99 kPa) for natural gas, or 10" W.C. (2.48 kPa) for propane gas, adjust regulator (if gas pressure is correct go to Step 10).

8.Remove cap from top of regulator.

9.With a screwdriver rotate regulator adjustment screw clockwise to increase, or counterclockwise to decrease, pressure until manometer shows correct reading.

10.Repeat steps 1 and 2.

11.Remove manometer fitting and replace plug in manifold.

12.Turn on main gas to range and light pilots.

13.Replace valve panels.

PAGE 24 OF 44

OWNERS MANUAL 1188716 (02/07)