Unit address: 001 ~ 128
Protocol: B1
2.4 Keyboard Setup
User need to setup network, passwords and special functions such as Uploading and Downloading programmed data from the dome cameras. To enter the Keyboard menu, press Ctrl + Menu. You will see the following menu. Joystick Up/Down scrolls menu items, push the stick to Right to enter the
Configuration
Network
Data Bank
Alarm
Exit
Configuration |
|
|
|
- Key Beep |
|
| : ON - enable key beep sound, |
|
|
| OFF - Disable beep sound. |
- |
|
| : OFF~60Min - After elapsed setup time, keyboard lock automatically. |
|
|
| OFF - Disable Auto |
|
|
| User needs login password to operate Keyboard again. |
- Chg User Pin | - |
| Change 4digit of user password. |
CurrentPin | : | Enter 4 digits of current user’s password. | |
NewPin |
| : | Enter 4 digits of new password. |
ConfirmPin : Confirm 4 digits of new password. | |||
- Chg Admin Pin | - |
| Change 4 digits of administrator’s password. |
CurrentPin | : | Enter 4 digits of new password. | |
NewPin |
| : | Enter 4 digits of new password. |
ConfirmPin : | Confirm 4 digits of new password. |
Note) Factory default Administrator’s password is 9999+Enter and user password is 1111+Enter. If you forgot your own password, contact service personnel or distributor.
- Rescan Domes | Scan newly installed dome cameras without turn off the Keyboard power. |
- Save and Exit | Save the programmed data and return to the previous Menu |
| (Exit without saving if you press ESC key) |
Network | Setup properties of devices to be connected. |
- Set Baud rate
Dome : 2400~230K Correspond with dome setting (9600bps)
MUX : 2400~230K
DVR485 : 2400~230K
DVR232 : 2400~230K Save and Exit
14