Speco Technologies KBD-927 Select Camera of Device menu on the above menu, RS232/TEXT IN, Parity

Models: KBD-927

1 33
Download 33 pages 38.97 Kb
Page 21
Image 21
Select Camera of Device menu on the above menu.

Select Camera of Device menu on the above menu.

PTZ set up on the above Setup menu

Select TEXT IN/PTZ after PTZ is installed, and then set-up as below

RS232/TEXT IN

Baud Rate

Parity

Data

Stop

Usage

 

 

 

 

 

 

RS232

9600

None

8

1

Remote Control

 

 

 

 

 

 

TEXT IN/PTZ

9600

None

8

1

PTZ Control

 

 

 

 

 

 

1)After installing Camera, and RS232 & TEXT IN/PTZ setup, the installation with dome camera is basically completed. Please refer to manual of SDR for the other installation.

2)Press the related number of a controller which correspondent to unit ID of SDR. Then press DVR button and adjust unit ID of a controller. Unit ID is not allowed number “0”.

3)Make sure if any change is appeared on screen to press PTZ set up on the above Setup menu button of a controller for basic testing. If there’s no change appeared, check cable connection and installation again.