Speco Technologies KBD-927 instruction manual Install with IDR series, IDR Connection Diagram

Models: KBD-927

1 33
Download 33 pages 38.97 Kb
Page 22
Image 22
2.7 Install with IDR series

2.7 Install with IDR series

22 AWG UTP CABLE

J-BOX(FRONT)

J-BOX(REAR)

 

 

DATA2

DATA1

WIRE CONNECTION

DOME JUNCTION BOX

R(T)X+ DOME1 +

R(T)X- DOME1 -

CONVERTER

JUNCTION BOX

TX+(RS-485)

DOME2 +

TX-(RS-485)

DOME2 -

RS-232 CABLE

IDR SERIES

RS-232C to RS-485

CONVERTER

Figure 11 – IDR Connection Diagram

If user wants to connect with IDR, please proceed as the following order.

1)Connect RS-232C cable between RS-232C Port of IDR and DVR port of the J-box. ( This connection enables IDR control remotely from KBD controller)

2)Plug the RS-232C TO RS-485 converter in the RS-232C Port of IDR. Connect wires between the TX(+/-) of converter and Data2(+/-) of J-Box.

(This connection enables IDR PTZ control from KBD controller)

3)How to setup the controller.

A.SWITCH THE KBD controller ON

B.INPUT PASSWORD (Factory Setting is 9999)

C.Open the menu of the KBD controller by pressing Ctrl + Menu Key.

D.Set as below in Network menu.

Set Baud Rate

 

Dome

:

9600

 

Mux

:

9600

 

DVR485 :

9600

 

DVR232 :

9600

 

Com Ports

 

 

 

Dome

:

Dome

 

Mux

:

None

 

DVR485 : AUX IN

 

DVR232 : IDR

 

 

 

4) How to setup IDR

 