Installation
Supply Injection System
Number of liquid supply connections | 2 |
| |
|
|
Liquid supply connection size, | 3/8 (9.52) |
in. (mm) | or |
| 1/4 (6.35) |
|
|
WARNING
Wear eye and hand protection when handling chemicals; always avoid direct contact with raw chemicals. Read the manufacturer’s directions for accidental contact before handling chemicals. Ensure an
SW016
3
2
1
FLW2116N
1Injection Point
2Nozzle
3Supply Dispenser Pump Outlet
Figure 12
A junction box on the rear panel houses a terminal strip which furnishes supply output signals for the supply injection pumps. Refer to Figure 13 for the injection interface label.
CHEMICAL INJECTION
ELECTRICAL INTERFACE
| YELLOW |
| |
SOFTENER |
| SOFTENER | |
DISPENSER |
| ||
YELLOW/BLACK | RELAY | ||
CONNECTION | |||
| |||
| RED |
| |
DETERGENT |
| DETERGENT | |
DISPENSER |
| ||
RED/BLACK | RELAY | ||
CONNECTION |
NO CONNECTION
TERMINAL
BLOCK
NOTE: Normally Open Contacts.
Contacts Close to Start Chemical Injection. Maximum Load Connection per Contact: 1A @ 120VAC/240VAC
801653R1
FLW2028N
Figure 13
These terminals may be used to provide signals to the supply injection system but must not be used to provide power to the actual pump.
Any injection system pump which requires
110 VAC must be powered by a separate external power source.
Control Function TestThe washer should be cleaned after the installation is complete. A function test should then be executed on the unloaded machine:
1.Check the power supply for such characteristics as correct voltage, phase, and cycles to be certain they are correct for the washer.
2.Open manual
3.Apply power to the washer.