
Installation
NOTE: Some models come without an electrical plug installed. If washer is not hard wired (refer to Figure 15), a suitable plug that meets local electrical standards, including earthing requirements, must be installed. Refer to the washer nameplate for proper voltage and Hertz the washer is designed to operate on. Refer to Figure 51.
100 Volt/50 HertzThe washer is designed to be operated on a separate polarized
50Hertz,
15ampere fuse, equivalent fusetron or circuit breaker.
DO NOT OPERATE OTHER APPLIANCES ON THE SAME CIRCUIT WHEN THE WASHER IS OPERATING.
100 Volt/60 HertzThe washer is designed to be operated on a separate polarized
15 ampere fuse, equivalent fusetron or circuit breaker.
DO NOT OPERATE OTHER APPLIANCES ON THE SAME CIRCUIT WHEN THE WASHER IS OPERATING.
240 Volt/50 HertzThe washer is designed to be operated on a separate polarized
50Hertz,
10ampere fuse, equivalent fusetron or circuit breaker.
DO NOT OPERATE OTHER APPLIANCES ON THE SAME CIRCUIT WHEN THE WASHER IS OPERATING.
240 Volt/60 HertzThe washer is designed to be operated on a separate polarized
10 ampere fuse, equivalent fusetron or circuit breaker.
DO NOT OPERATE OTHER APPLIANCES ON THE SAME CIRCUIT WHEN THE WASHER IS OPERATING.
230 Volt/50 HertzThe washer is designed to be operated on a separate polarized
50Hertz,
10ampere fuse, equivalent fusetron or circuit breaker.
DO NOT OPERATE OTHER APPLIANCES ON THE SAME CIRCUIT WHEN THE WASHER IS OPERATING.
The washer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. The washer is equipped with a cord having an
WARNING
Improper connection of the equipment- grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the washer is properly grounded.
W300
DO NOT modify the plug provided with the washer – if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
If the laundry room’s electrical supply does not meet the above specifications and/or if you are not sure the laundry room has an effective ground, have a qualified electrician or your local electrical utility company check it and correct any problems.
WARNING
Any disassembly requiring the use of tools must be performed by a suitably qualified service person.
W299
18 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 38970 |