Congratulations and thank you for purchasing the latest addition to the growing Stanton family of professional DJ gear. Sporting a new attitude and a fresh, modern look, the Stanton C.504 is a dual rackmount CD player with designed to give club and mobile DJs a powerful, yet simple tool to mix, cre- ate, and perform their best.

Designed for DJs who want solid, reliable performance and the latest technology, the workhorse C.504 boasts powerful features like scratching, seam- less looping, programmable hot cue points, plus digital Key Lock and Key Shift functions for creating more exciting mixes. Thoughtfully designed and engineered to give you the most intuitive and instinctual experience possible, the C.504 delivers all these features in a logical layout with quality com- ponents at a price working DJs can afford. We’re proud to bring you the new look, feel, and sound of Stanton.

SAFETY PRECAUTIONS

WARNING: TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.

CAUTION:

Handle the power supply cord carefully. Do not damage or deform the power supply cord. If it is damaged, cut, or deformed, it may cause electric shock or malfunction when used. When removing from wall outlet, be sure to remove by holding the plug attachment and not by pulling the cord.

In order to prevent electric shock, do not open or disassemble. If a problem occurs, contact your dealer or an authorized service center.

Do not place metal objects or spill liquid inside the CD player. Electric shock or malfunction may result.

To reduce the risk of electric shock, do not remove any cover. No user-serviceable parts inside. Refer servicing to qualified service personnel only.

The lightning flash with arrowhead symbol within the equilateral triangle is intended to alert the user to the presence of un-insulated “dangerous volt-

age” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock.

The exclamation point within the equilateral triangle is intended to alert the user to the presence of important operation and maintenance (servicing) instructions in the literature accompanying this appliance.

Product complies with DHHs rule 21 CFR subchapter J in effect at date of manufacture.

To prevent electric shock, do not use this (polarized plug) with an extension cord, receptacle or other outlet unless the blades can be fully inserted to prevent blade exposure.

NOTE:

This CD player uses a semiconductor laser. For optimal operation, it is recommended that this unit be used in a room with temperatures between 41°F / 5°C and 95°F / 35°C.

This unit may cause interference to radio and television reception.

CAUTION:

USE OF CONTROLS OR ADJUSTMENTS OR REFORMANCE OF PROCEDURES OTHER THAN THOSE SPECIFIED HEREIN MAY RESULT IN HAZ- ARDOUS RADIATION EXPOSURE.

THE COMPACT DISC PLAYER SHOULD NOT BE ADJUSTED OR REPAIRED BY ANYONE EXCEPT PROPERLY QUALIFIED SERVICE PERSONNEL.

DOUBLE INSULATED – WHEN SERVICING, USE ONLY IDENTICAL REPLACEMENT PARTS

Please record and retain the model and serial numbers of your CD player as shown on the rear of the unit.

Model #:____________________

Serial #:_____________________

SAFETY INSTRUCTIONS

Read these instructions.

2 Keep these instructions.

3 Heed all warnings.

4 Follow all instructions.

5 Do not use this apparatus near water.

6 Clean only with dry cloth.

7 Do not block any ventilation openings. Install in accordance with the manufacturerÅfs instructions.

8 Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.

9 Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other.

Agrounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.

10 Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.

11 Only use attachments/accessories specified by the manufacturer.

12 Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.

Page 2
Image 2
Stanton C.504 manual Safety Precautions, Safety Instructions

C.504 specifications

The Stanton C.504 is a versatile and innovative aircraft designed to meet the demands of modern aviation. Known for its reliability and efficiency, the C.504 has garnered attention from both commercial and private sectors. Its development incorporates state-of-the-art technologies, making it a significant addition to the fleet of multi-purpose aircraft.

One of the standout features of the C.504 is its impressive capacity. Designed to accommodate up to 19 passengers in a comfortable cabin, the aircraft is ideal for regional travel. The spacious interior allows for flexible seating arrangements and can be easily reconfigured for cargo transport, making it a practical choice for diverse operations.

Powered by twin high-performance turboprop engines, the C.504 offers exceptional performance and fuel efficiency. The engines are designed to provide a balance of power and economy, resulting in lower operational costs. Additionally, the aircraft boasts a maximum cruise speed of approximately 300 knots, allowing for quick transit times between destinations.

The C.504 is also equipped with advanced avionics systems that enhance safety and navigation. The flight deck features a modern glass cockpit with integrated displays that provide pilots with real-time information and improve situational awareness. These technologies not only streamline flight operations but also contribute to safer flying experiences.

Another notable characteristic of the C.504 is its range. With a maximum range of over 1,200 nautical miles, the aircraft is capable of connecting remote locations and underserved markets. This extended range opens up new opportunities for regional airlines and charter operators, allowing them to serve a broader customer base.

In terms of design, the C.504 incorporates aerodynamically efficient profiles that reduce drag and improve performance. The aircraft's wing configuration contributes to its stability and handling, making it suitable for various flying conditions. Moreover, the robust landing gear system ensures that the C.504 can operate from a variety of airfields, including those with less-than-ideal runway conditions.

Overall, the Stanton C.504 represents a significant step forward in the evolution of regional aircraft. With its blend of capacity, performance, and advanced technology, it stands poised to fulfill the increasing demands of the aviation industry while providing a comfortable and efficient travel experience for passengers and operators alike.