Chapter 4: Controls
4-1 Control Panel Indicator Lights and Switches
Rocker Switches
System ON/OFF Rocker Switch
Used to
Dryer ON/Sequence Shutdown Rocker Switch
Used to start the dryer. Move this switch to the Sequence Shutdown position to turn off the process heaters, finish the regeneration cycle and then turn off the dryer.
Optional Alarm Silence Rocker Switch
Press the Alarm Silence switch to silence the horn when a high temperature alarm activates. The alarm repeats every five minutes until the problem causing the alarm condition is cleared.
Indicating Lights
Indicator | Name | Description |
| Regen Blower | The Regen Blower On indicator lights when the |
G | On Light | regeneration blower energizes. |
|
| |
G | Left Bed In | The Left Bed In Regen LED lights when the left bed |
Regen Light | is in regeneration. | |
G | Left Bed Heater | The Left Bed Heater indicator lights when the left |
Light | bed regenerates and is in the | |
|
| regeneration cycle. |
G | Right Bed In | The Right Bed In Regen LED lights when the right |
Regen Light | bed is in regeneration. | |
G | Right Bed Heater | The Right Bed Heater indicator lights when the right |
Light | bed regenerates and is in the | |
|
| regeneration cycle. |
| Process Blower | The Process Blower On indicator lights when the |
G | On Light | process blower energizes. |
G | Process Heater | The Process Heater On indicator lights when the |
On Light | process air heater is energized. | |
| Low Compressed | The Low Compressed Air alarm indicator lights |
R | Air Light | when the dryer compressed air supply drops below |
|
| 60 psi (413kPa/ 4.13 bars). Upon loss of |
Cabinet Series Dehumidifying Dryer | 15 |