Output LED Indicators
| Name | Description |
|
|
|
| Blower On (O/0) | The Blower On indicator lights when the blower |
|
| energizes. |
|
|
|
| Process Heater | The Process Heater Enable activates the process |
| Enable (O/2) | heater. The indicator lights when the process heater |
|
| is energized. This condition occurs when no blower |
|
| failures or high temperature conditions exist. |
|
|
|
| Left/Right Regen | The Regen Heater Output indicator lights when the |
| Heater Output | indicated bed regeneration heater energizes. |
| (O/3, O/4) |
|
| Right Bed | The right Bed Regeneration Output activates the |
| Regeneration | right bed regeneration indicator lights when the |
| Output (O/5) | right bed regenerates. When this indicator is off, the |
|
| left bed is energized. |
|
|
|
| High Regen | When ON, indicates a high regen temp condition in |
| Temp Alarm | either the left or right bed. |
| (O/6) |
|
|
|
|
| Alarm Horn | The Alarm Horn Strobe Output indicates a high |
| Output (O/7) | process temperature condition and optional critical |
| Optional | low level at the drying hopper. |
|
|
|
Status LED Indicators | ||
|
|
|
| Name | Description |
|
|
|
| Power | The Power indicator lights when the PLC receives |
|
| 115V control power. |
|
|
|
| Run | The Run indicator lights when the PLC executes the |
|
| program in normal conditions. |
|
|
|
| Fault | The Fault indicator lights when the PLC program |
|
| has a problem or failure condition. |
|
|
|
| Force | The Force indicator is not used. |
|
|
|
Cabinet Series Dehumidifying Dryer | 23 |