4-8 Setting the Shift on Dew Point

Our dehumidifying dryers shift air flow from the on-line desiccant bed to the regenerated desiccant bed, based on actual dew point demand, not fixed time cycles. After the off-line bed regenerates, the PLC controller waits for a high dew point signal from the process air dew point controller before switching beds. The PLC controller has a four (4) -hour timer override if it does not receive a signal from the dew point control.

„Set the shift on dew point set point to the highest process air moisture content you want to allow before the dryer shifts air flow to the regenerated desiccant bed. The dew point controller is set at the factory for -20ºF (-29ºC).

„To change the dew point setting, press the Up Arrow and Down Arrow buttons to the shift point you want.

4-9 Entering Operating Parameters to Select Modes

To enter the menu display:

1.Press the Display button for one second (keep the pressure on the button for about 1.5 to 2 seconds).

The screen displays .

2.Press the Up Arrow button to toggle through the different modes. The SV readout displays the mode you selected.

3.To switch parameters within a mode, press the Display button once more for about one and a half to two (1.5 to 2) seconds.

The PV readout displays the different parameters within each mode.

4.Use short presses on the Display button to display each parameter within a mode. The SV readout displays the different values for the parameter within a mode.

5.Press Up Arrow and Down Arrow buttons to set the higher or lower the values of a parameter.

6.Press Display button for about one and a half to two (1.5 to 2) seconds to move up a level back into the different modes.

7.Press Down Arrow button until Level 0 displays. Press the Display button for about one to one and a half (1 to 1.5) seconds to go to Operating mode.

4-10 Setting the High Dew Point Alarm

The high dew point alarm is factory set for -10ºF (-23ºC). The high dew point alarm will energize the “High Dew Point” light. Entering the Level 1 operating parameter changes the high dew point alarm setting. Use the following procedure to set the high dew point alarm:

1.Press and hold the Display button to access Level 0. The controller displays Level 0.

2.Press Up Arrow button to display Level 1. Lu-1 displays.

3.Press the Display button to select Level 1.

4.Press the Display button until the controller displays AL-1.

Cabinet Series Dehumidifying Dryer

27

Page 28
Image 28
Sterling 90-225 CFM, SDA 150-380 Setting the Shift on Dew Point, Entering Operating Parameters to Select Modes

SDA 150-380, 90-225 CFM specifications

The Sterling 90-225 CFM and SDA 150-380 series represent cutting-edge advancements in air compressor technology, designed for a wide range of industrial applications. Known for their reliability, efficiency, and superior performance, these units are essential tools for professionals seeking high-quality compressed air solutions.

One of the standout features of the Sterling 90-225 CFM series is its impressive flow rate. With a capacity range of 90 to 225 cubic feet per minute, these compressors offer ample airflow to power pneumatic tools and equipment while maintaining optimal pressure levels. The durability of the components used in the construction of this series ensures that it can withstand the rigors of heavy-duty operations while minimizing downtime.

The SDA 150-380 series further enhances this approach with its higher capacity range, accommodating between 150 to 380 CFM. This variant is particularly suitable for larger facilities and demanding applications where sustained airflow is essential. Both series are designed to adapt to various pressure requirements, making them versatile solutions for different industries, including manufacturing, construction, and automotive sectors.

A key technology featured in both series is the use of energy-efficient motors, which significantly reduce operational costs. These motors are designed to deliver high torque at low speeds, ensuring smooth operation and less wear on the compressor. Furthermore, the incorporation of advanced control systems allows for real-time monitoring and adjustments to optimize performance, ensuring that the compressors operate within desired parameters continuously.

Noise reduction is another critical aspect of both the Sterling and SDA series. Innovatively engineered with sound-attenuating materials, these compressors operate at lower decibel levels, providing a more pleasant working environment. This focus on user comfort doesn’t sacrifice performance, as the units are built to achieve maximum efficiency even at reduced noise levels.

The ease of maintenance is another important characteristic. Both models are equipped with user-friendly access points for essential components, simplifying routine checks and servicing procedures. This results in less downtime and improved reliability across the operational lifespan of the compressors.

In conclusion, the Sterling 90-225 CFM and SDA 150-380 series compressors set a benchmark in the industry, offering a blend of performance, efficiency, and user-friendly features that cater to various industrial needs. Their robust construction, advanced technology, and focus on user comfort make them ideal choices for businesses seeking to enhance productivity and reduce operational costs.