Recommendations for Cleaning and Replacing Filters

Turn off and/or lock out electrical power to the dryer.

Remove the threaded fastener securing the filter access cover, and then remove the cover.

Remove the nut on the center retaining rod to remove the filter cartridge.

Vacuuming

Try vacuum-cleaning a soiled filter first. Vacuuming removes most large particles and surface contaminants, and may suffice for the first time you clean a filter. Use a commercial-duty (recommended) or household vacuum cleaner. Vacuum the filter from the air intake (dirty) side only.

Cleaning with Compressed Air

Blow clean, dry compressed air up and down the pleats, blowing out the filter from the clean side. Remove loose dirt from the filter with compressed air or a water hose. Compressed air

should be less than 100 psi (689.5 kPa/6.89 bars). Use a 1/8”

(3 mm) dia. nozzle at least 2” (5 cm) away from the filter. Don’t shoot the air in a crisscross motion against the grain of the pleats—you may damage it.

Washing

As a last resort, wash the filter. However, do so only if the pressure drop is too high from fine dirt embedded in the filter, or if oily mist is present near the intake air location. Soak in a solution of FM 1400 or comparable detergent and warm water from five to ten minutes, then gently agitate for several minutes.

Rinse thoroughly with clean water to remove all detergent.

Caution! Let the filter dry completely before returning it to service! A damp filter can contaminate the closed loop system of the dryer.

Do not use a light bulb to dry the filter. You should get satisfactory filtration after second or third washings; however, dirt-holding capacity of the filter decreases after each washing.

After each cleaning:

Inspect the filter element. Briefly hold a light bulb behind the element and look for any fatigued paper or residual dirt. Inspect for holes and tears by looking though the filter toward a bright light. Check for damaged gaskets or dented metal parts. Do not re-use a damaged filter!

Inspect the end plates. Any damage here can allow air to bypass the filter.

Look for rust on the end plates and metal core. Rust particles can flake off and contaminate the dryer and resin.

Check the gasket for damage. A damaged gasket allows contaminants into the process. Replace as needed.

Allow the filter to dry before re-using. Circulate warm air at less than 160ºF (71ºC). Do not use a light bulb to dry the filter.

Cabinet Series Dehumidifying Dryer

36

Page 37
Image 37
Sterling SDA 150-380 Recommendations for Cleaning and Replacing Filters, Vacuuming, Cleaning with Compressed Air, Washing

SDA 150-380, 90-225 CFM specifications

The Sterling 90-225 CFM and SDA 150-380 series represent cutting-edge advancements in air compressor technology, designed for a wide range of industrial applications. Known for their reliability, efficiency, and superior performance, these units are essential tools for professionals seeking high-quality compressed air solutions.

One of the standout features of the Sterling 90-225 CFM series is its impressive flow rate. With a capacity range of 90 to 225 cubic feet per minute, these compressors offer ample airflow to power pneumatic tools and equipment while maintaining optimal pressure levels. The durability of the components used in the construction of this series ensures that it can withstand the rigors of heavy-duty operations while minimizing downtime.

The SDA 150-380 series further enhances this approach with its higher capacity range, accommodating between 150 to 380 CFM. This variant is particularly suitable for larger facilities and demanding applications where sustained airflow is essential. Both series are designed to adapt to various pressure requirements, making them versatile solutions for different industries, including manufacturing, construction, and automotive sectors.

A key technology featured in both series is the use of energy-efficient motors, which significantly reduce operational costs. These motors are designed to deliver high torque at low speeds, ensuring smooth operation and less wear on the compressor. Furthermore, the incorporation of advanced control systems allows for real-time monitoring and adjustments to optimize performance, ensuring that the compressors operate within desired parameters continuously.

Noise reduction is another critical aspect of both the Sterling and SDA series. Innovatively engineered with sound-attenuating materials, these compressors operate at lower decibel levels, providing a more pleasant working environment. This focus on user comfort doesn’t sacrifice performance, as the units are built to achieve maximum efficiency even at reduced noise levels.

The ease of maintenance is another important characteristic. Both models are equipped with user-friendly access points for essential components, simplifying routine checks and servicing procedures. This results in less downtime and improved reliability across the operational lifespan of the compressors.

In conclusion, the Sterling 90-225 CFM and SDA 150-380 series compressors set a benchmark in the industry, offering a blend of performance, efficiency, and user-friendly features that cater to various industrial needs. Their robust construction, advanced technology, and focus on user comfort make them ideal choices for businesses seeking to enhance productivity and reduce operational costs.