Sterling SDA 150-380, 90-225 CFM Available Option Boards, Parameter, Setting range, Factory

Models: SDA 150-380 90-225 CFM

1 52
Download 52 pages 28.89 Kb
Page 45
Image 45

 

 

Initialize

 

 

 

 

 

Setup

6UE1 Control Output 1

Heat/Cool/Alarm 1/Alarm 2/Alarm 3/

Heat

Default

 

 

Assignment

 

 

LBA

 

 

Setup

6UE2 Control Output 2

Heat/Cool/Alarm 1/Alarm 2/Alarm 3/

AL-1

Default

 

 

Assignment

 

 

LBA

 

 

Setup

Sub 1 Auxiliary Output

 

Alarm 1/Alm 2/Alm 3/LBA/S.ERR/E333

AL-1

Default

 

 

1 Assignment

 

 

 

 

 

Setup

ALE1 Alarm 1 Type

 

0 to 11

2

Default

Setup

AL1n Alarm 1 open in

 

NO/NC

NO

Default

 

 

alarm

 

 

 

 

 

Setup

ALE2 Alarm 2 Type

 

0 to 11

2

Default

Setup

AL2n Alarm 2 open in

 

NO/NC

NO

Default

 

 

alarm

 

 

 

 

 

Setup

ALE3 Alarm Type

 

0 to 11

2

Default

Setup

AL3n Alarm 3 open in

 

NO/NC

NO

Default

 

 

alarm

 

 

 

 

 

Setup

6rEu Direct/Reverse

 

OR-R/OR-D

OR-R

Default

 

 

Operation

 

 

 

 

 

 

 

 

 

 

 

 

Mode

 

Parameter

 

Setting range

Default

Factory

 

 

 

 

 

 

 

setting

Expansion

SL-H Set Point Upper

 

SP Lower Limit +1 to Scaling Upper

1300

400.0

 

 

Limit

 

Limit

 

 

Expansion

SL-L Set Point Lower

 

Scaling Upper Limit to SP Lower Limit

-200

0

 

 

Limit

 

 

 

 

Expansion

CnEL PID/ON/OFF

 

PID/ON/OFF

PID

Default

Expansion

SE ST Adaptive Tuning

OFF/ON

OFF

Default

 

 

(Fuzzy)

 

 

 

 

Expansion

SE-b ST Stable Range

0.1 to 999.9 °C/F

15

Default

Expansion

ALFA α

 

0.01 to 1.00

0.65

Default

Expansion

AE-G AT Calculated

 

0.1 to 10.0

1.0

Default

 

 

Gain

 

 

 

 

Expansion

rESE Standby

 

0/1

0

Default

Sequence Reset

 

 

 

 

 

Setting Method

 

 

 

 

Expansion

rEE Automatic Return

 

0 to 99 SEC

0

Default

 

 

of Display Mode

 

 

 

 

Expansion

AE-H AT Hysteresis

 

0.1 to 9.9% FS

0.2

Default

Expansion

LbAb LBA Detection

 

0.0 to 999.9% FS

0.2

Default

 

 

Width

 

 

 

 

Option Boards

Available Option Boards

Cabinet Series Dehumidifying Dryer

44

Page 45
Image 45
Sterling SDA 150-380, 90-225 CFM installation manual Available Option Boards, Parameter, Setting range, Factory