„NEVER place your hands or any part of your body in any dangerous location.

„NEVER operate, service, or adjust the dryer without appropriate training and first reading and understanding this manual.

„NEVER try to pull material out of the dryer with your hands while it is running!

„Before you start the dehumidifying dryer, check the following:

Remove all tools from the dryer;

Be sure no objects (tools, nuts, bolts, clamps, bars) are laying in the area;

„If your dryer has been inoperative or unattended, check all settings before starting.

„At the beginning of your shift and after breaks, verify that the controls and other auxiliary equipment are functioning properly.

„Keep all safety guards in place and in good repair. NEVER attempt to bypass, modify, or remove safety guards. Such alteration is not only unsafe, but will void the warranty on your equipment.

„When changing control settings to perform a different mode of operation, be sure selector switches are correctly positioned. Locking selector switches should only be adjusted by authorized personnel and the keys removed after setting.

„Report the following occurrences IMMEDIATELY:

unsafe operation or condition

unusual dryer action

leakage

improper maintenance

NEVER stand or sit where you could slip or stumble into the dehumidifying dryer while working on it.

„DO NOT wear loose clothing or jewelry, which can be caught while working on the dryer. In addition, cover or tie back long hair.

„Clean the dehumidifying dryer and surrounding area DAILY, and inspect the machine for loose, missing or broken parts.

„Shut off power to the dryer when it is not in use. Turn the switch to the OFF position, or unplug it from the power source.

Maintenance Responsibility

Proper maintenance is essential to safety. If you are a maintenance worker, you must make safety a priority to effectively repair and maintain equipment.

Before removing, adjusting, or replacing parts on a machine, remember to turn off all electric supplies and all accessory equipment at the machine, and disconnect and lockout electrical and pneumatic power. Attach warning tags to the disconnect switch and air shutoff valve.

When you need to perform maintenance or repair work on a dehumidifying dryer above floor level, use a solid platform or a hydraulic elevator. If there is a permanently installed catwalk on your dryer, use it. The work platform should have secure footing and a place for tools and parts. DO NOT climb on the dehumidifying dryer, machines, or work from ladders.

Cabinet Series Dehumidifying Dryer

8

Page 9
Image 9
Sterling SDA 150-380, 90-225 CFM installation manual Maintenance Responsibility

SDA 150-380, 90-225 CFM specifications

The Sterling 90-225 CFM and SDA 150-380 series represent cutting-edge advancements in air compressor technology, designed for a wide range of industrial applications. Known for their reliability, efficiency, and superior performance, these units are essential tools for professionals seeking high-quality compressed air solutions.

One of the standout features of the Sterling 90-225 CFM series is its impressive flow rate. With a capacity range of 90 to 225 cubic feet per minute, these compressors offer ample airflow to power pneumatic tools and equipment while maintaining optimal pressure levels. The durability of the components used in the construction of this series ensures that it can withstand the rigors of heavy-duty operations while minimizing downtime.

The SDA 150-380 series further enhances this approach with its higher capacity range, accommodating between 150 to 380 CFM. This variant is particularly suitable for larger facilities and demanding applications where sustained airflow is essential. Both series are designed to adapt to various pressure requirements, making them versatile solutions for different industries, including manufacturing, construction, and automotive sectors.

A key technology featured in both series is the use of energy-efficient motors, which significantly reduce operational costs. These motors are designed to deliver high torque at low speeds, ensuring smooth operation and less wear on the compressor. Furthermore, the incorporation of advanced control systems allows for real-time monitoring and adjustments to optimize performance, ensuring that the compressors operate within desired parameters continuously.

Noise reduction is another critical aspect of both the Sterling and SDA series. Innovatively engineered with sound-attenuating materials, these compressors operate at lower decibel levels, providing a more pleasant working environment. This focus on user comfort doesn’t sacrifice performance, as the units are built to achieve maximum efficiency even at reduced noise levels.

The ease of maintenance is another important characteristic. Both models are equipped with user-friendly access points for essential components, simplifying routine checks and servicing procedures. This results in less downtime and improved reliability across the operational lifespan of the compressors.

In conclusion, the Sterling 90-225 CFM and SDA 150-380 series compressors set a benchmark in the industry, offering a blend of performance, efficiency, and user-friendly features that cater to various industrial needs. Their robust construction, advanced technology, and focus on user comfort make them ideal choices for businesses seeking to enhance productivity and reduce operational costs.