Electrical Features

Dryer AMP Draw

 

 

 

 

CFM

 

 

 

600

850

 

1000

1250

1500

2000

2500

3000

 

 

 

 

 

 

 

 

 

 

 

 

Standard voltage Low Heat (Electric Dryers)

 

 

 

Full load Amps

 

 

208v/3/60Hz.

152

217

 

249

314

378

 

N/A

 

230v/3/60Hz.

137

196

 

225

284

342

 

 

 

 

 

 

400v/3/50Hz.

79

113

 

129

163

197

270

339

424

460v/3/60Hz.

69

98

 

112

142

171

234

294

370

575v/3/60Hz.

55

78

 

90

114

137

188

236

295

Standard voltage High Heat (Electric Dryers)

 

 

 

Full load Amps

 

 

208v/3/60Hz.

207

296

 

342

430

 

N/A

 

230v/3/60Hz.

187

267

 

309

389

 

 

 

 

 

 

 

400v/3/50Hz.

108

154

 

178

224

269

366

N/A

460v/3/60Hz.

94

134

 

154

194

234

318

399

494

575v/3/60Hz.

75

107

 

123

156

187

254

319

395

Standard voltage (Gas Dryers)

 

 

 

Full load Amps

 

 

208v/3/60Hz.

36

47

 

48

61

75

120

150

191

230v/3/60Hz.

33

43

 

44

55

67

109

136

173

400v/3/50Hz.

19

 

25

32

39

62

78

99

460v/3/60Hz.

16

 

22

28

34

54

67

87

575v/3/60Hz.

13

 

17

22

27

43

54

69

Electrical Options

9 Denotes availability

Option Description

 

 

 

 

CFM

 

 

 

600

850

 

1000

1250

1500

2000

2500

3000

 

 

 

 

 

 

 

 

 

 

 

 

AP1 control

 

 

 

 

 

 

 

 

 

(Includes: 4”x2” touch screen and dew point monitoring, 7

 

 

 

 

9

 

 

 

day timer, dirty filter indication, & temperature setback.)

 

 

 

 

 

 

 

 

 

Hopper mounting of the process heater box

 

 

9

 

 

9

 

Remote operator interface

 

 

 

 

CF

 

 

 

Redundant process temperature safety

 

9 (Standard w/High Performance)

 

Ethernet module for remote communication w/ Data logging

 

 

 

 

9

 

 

 

CSA approval

 

 

 

 

9

 

 

 

UL rating

 

 

 

 

9

 

 

 

Supply voltages 400/3/50 (includes CE compliance)

 

 

 

 

9

 

 

 

Audible & Visual Alarm

 

9 (Standard w/High Performance)

 

Large Dehumidifying Dryers

Functional Description

25

Page 25
Image 25
Sterling SDA AP-1 specifications Denotes availability