1.Remove the bolts securing the process heater access cover.
2.Sketch the heater wiring configuration so the heaters may be
3.Remove the jumper bars and wires for the heater plate assembly(ies) being removed or replaced.
4.Remove the bolts securing the heater plate assembly and slide out the assembly. Avoid damaging the gaskets.
5.Remove individual heaters for replacement by removing the large brass nuts and washers.
6.
Caution! Heater loops should not touch each other. "Hot spots" will lead to premature heater failure.
7.
8.
Figure 16: Process Heater Box Assembly | Stainless Steel | ||
|
|
| Heater Housing |
| High |
| Cover |
| Temperature | Heater Elements | |
| Gasket | ||
| Double Wall |
| |
|
|
| |
|
| Stainless Steel |
|
|
| Heater |
|
Heater Elements |
| Housing |
|
|
| High |
|
Heater Element |
| Temperature |
|
Mounting Plate |
| Gasket |
|
|
| Heater Element |
|
|
| Mounting Plate |
|
| Double Wall |
|
|
| Stainless Steel |
|
|
| Heater |
|
|
| Housing |
|
|
| High |
|
|
| Temperature |
|
|
Heater Assembly | Gasket |
|
|
|
|
| |
Gude Bars |
|
| Heater Assembly |
Stainless Steel |
|
| Gude Bars |
|
|
| |
Heater Housing |
|
|
|
Cover |
|
|
|
Hex Nut For | Heater Element |
|
|
Securing the Heater | Mounting Hex Nut |
|
|
Wire | High Temperature | Heater Element |
|
|
| ||
Washer | Washer / Gasket |
|
|
Heater Wire with |
|
|
|
Crimped on Closed |
|
|
|
Loop Connector |
|
|
|
Heater Mounting | Heater Element | Heater Assembly |
|
Bulkhead Fitting | Guide Bar |
| |
Plate |
|
|
|
Replacing the Regeneration Heater (Electric Dryers)
The regeneration heaters are wired in the delta formation, mounted in the core of the desiccant tanks.
DANGER! Disconnect and lock out power before heater replacement.
Large Dehumidifying Dryers | Maintenance | 62 |