(System Backup Screen)

ACS Dryer control version 2.000 introduces a system backup feature.

Pressing SAVE SETTINGS will save the system variables for later recall.

Pressing RESTORE SETTINGS will restore previously saved values.

Pressing RESTORE FACTORY DEFAULTS will return the dryer to its factory default state, namely:

CONVEYING:

NO CONVEYING UNITS AVAILABLE - CONVEYING DISABLED

DRYER OPTIONS:

 

TEMPERATURE IN FAHRENHEIT

 

STANDARD HEAT

 

OVERDRY PROTECTION DISABLED

 

AUTO START TIMER DISABLED

 

DRYER VALUES:

 

ALARM SILENCE DURATION

99 MIN

PASSWORD - OPERATOR

0000

PASSWORD SUPERVISOR

1234

PASSWORD OPERATOR DURATION

10 MIN

PASSWORD SUPERVISOR DURATION

10 MIN

DEWPOINT HIGH LIMIT ALARM VALUE

30 DEGF

(ALARM DISABLED)

 

OVERDRY SET BACK TEMPERATURE

170 DEGF

OVERDRY SET BACK SETPOINT

100 DEGF

OVERDRY SET UP TEMPERATURE

90 DEGF

PROCESS AIR TEMP. SETPOINT

180 DEGF

PROCESS AIR HI DEVIATION VALUE

35 DEGF

PROCESS AIR LO DEVIATION VALUE

-35 DEGF

REGENERATION AIR SETPOINT

450 DEGF

PROCESS ACTUAL VALUE OFFSET

0.0 DEGF

REGEN ACTUAL VALUE OFFSET

0.0 DEGF

SERVICE

(Service Menu Screen)

Large Dehumidifying Dryers

Controls

47

Page 47
Image 47
Sterling SDA AP-1 specifications System Backup Screen, Service Menu Screen