Sterling operating instructions SSE-2 5.1. Maintenance intervals, Servicing the conveyor

Models: SSE-2

1 58
Download 58 pages 63.95 Kb
Page 25
Image 25
SSE-2

SSE-2

5.1. Maintenance intervals

Daily:

Check warning signs on equipment for good

 

legibility and completeness

 

Clean the sieve / filter (= units with active cleaning):

 

Use compressed air to blow through the sieve / filter

 

(according to the accumulation of dust)

Monthly:

Check function of the device plug

Every 6 months:

Check all electrical and mechanical connections for tight fit

 

Check setting of the level sensor (if present, optional)

 

Replace the sieve / filter (= units with active cleaning)

 

(according to the accumulation of dust)

Annually:

Replace outlet valve sealing.

 

Adjust valve switch

After 1000

 

operating hours:

Replace carbon brushes

F

The given maintenance intervals are average values.

Check whether in your individual case the maintenance intervals must be shortened.

5.2. Servicing the conveyor

»

Disconnect the unit from mains supply by the device plug.

Depressurize all system sections of the equipment (only units with active cleaning).

Disassembly the unit.

SM4-615

Maintenance 5-3