8.6. Material feed

Suction pipes type MV may be tilted by approx. 45 degrees in either direction to the vertical. Addi- tional fastening is not required.

When conveying from the bottom of storage containers (silos), a suction box with 1-3 suction pi- pes is required.

The connection of the suction pipes must be carried out with a piece of flexible line to provide suffi- cient movement.

Please observe that the length of the hose should not exceed 3 meters (10 feet). Push the free pipe end into the flexible line to a depth of approx. 4-5 cm (1.5" - 2"). Connect both parts by means of a hose clamp.

8.7. Mounting the suction pipe MV

The suction pipe consists of an inner pipe (A) and an outer pipe (B) which can be offset against each other.

Connect the inner pipe with the straight end to a flexible hose:

Push the free pipe end into the flexible line to a depth of approx. 4-5 cm (1.5" - 2").

Connect both parts by means of a hose clamp.

Please observe that the length of the hose should not exceed 3 meters (10 feet).

Please check that the outer pipe is not covered as it provides for unhindered access of ambient air.

F

When conveying from silos, material hoppers and storage containers, a

suction box with 1-3 suction pipes is required.

BA

MV

Assembly instructions 8-6