No. | Function | ||
1 | Shifts the cursor (∇) specifying a day to the right. | ||
2 | Sets or cancels (reset) a specified day. | ||
3, 4 | Sets a time or ON/OFF time width. (hours, minutes) | ||
5 | Monitors the parameters set for an operation during an operation. | ||
6 | Sets parameters. (Write) | ||
7 | Sets a time adjustment mode. | ||
8 | Specifies a cyclic operation, or sets a pulse width. (Not used) | ||
9 | Specifies a day substitution operation. (Copy) | ||
10 | Cancels the parameters set for each circuit, or a day substitution operation. | ||
11 | P1: | Circuit 1 programming mode. | |
P2: | Circuit 2 programming mode. | ||
| Run: | Run mode. | |
12 | ON: | Turns on the output regardless of the program | |
AUTO: | Executes according to the program. | ||
| OFF: | Turns off the output regardless of the program. | |
13 | TIMER: Executes an ordinary timer or cyclic operation. | ||
PULSE: Executes a | |||
| |||
14 | Specifies automatic or manual operation following a power failure. | ||
15 | The Output indicator will light when the timer output is energized. (Dryer On) | ||
16 | Displays the time at which the next operation will be preformed. |
Note: For timer operation, the System Power rocker switch must be in the ON position and the
Dryer/on Sequence Shutdown rocker switch must be in the SEQUENCE SHUTDOWN position.
•The OUT switch (#12) should be set to AUTO.
•The
•Program 1 is operational; Program 2 is not used.
Note: To bypass the
Programming the Optional Timer
Setting the Current Day of the Week, Hour, and Minute
1.Apply main power to the dryer.
2.The
3.Hold the TIME ADJ key (#7) for 1 second or longer.
4.Press the SHIFT key (#1) to move the cursor (∇) to the desired day position. Holding down this key advances the day.
5.Press the SET key (#2). The bar mark will turn on under the chosen day.
6.Press the h key (#3) to adjust the hours. Holding the key will rapidly advance the hour.
7.Press the m key (#4) to adjust the minutes.
Cabinet Series Dehumidifying Dryer | 30 |