Sterling Plumbing 90 Option Type, RE232C, RS-485, Event Input, Transfer Output, Mode, Parameter

Models: 100 150 90 Cabinet Series Dehumidifying Dryer 225

1 52
Download 52 pages 20.74 Kb
Page 46
Image 46

Option Type

 

RE232C

 

 

RS-485

 

Event Input

 

Transfer Output

Board Number

 

E53-CK01

 

E53-CK03

 

E53-CKB

 

 

E53-CKF

 

 

 

 

 

 

 

 

 

 

Mode

Parameter

 

 

 

 

Setting range

Default

 

Factory

 

 

 

 

 

 

 

 

 

 

 

 

 

setting

Option

Eu-A Multi-SP Function

 

 

0/1

 

 

0

 

Default

Option

Eu-1 Event Input Assign 1

 

 

STOP/MAN

STOP

 

Default

Option

SbCE Communication Stop Bit

 

½ BITS

 

2

 

Default

Option

Len Comm. Data Length

 

 

7/8 BITS

 

7

 

Default

Option

PrEY Commication Parity

 

 

None/Even/Odd

 

Even

 

Default

Option

6PS Comm. Baud Rate

 

 

1.2/2.4/4.8/9.6/19.2

9.6 kbps

 

Default

Option

U-n6 Comm. Unit No.

 

 

0 to 99

 

0

 

Default

Option

Er-E Transfer Output Type

 

 

SP/SP-M/PV/O/C-O

 

SP

 

Default

Option

Er-H Xfer Output Upper Limit

 

 

5

 

 

5

 

Default

Option

Er-L Xfer Output Lower Limit

 

 

5

 

 

5

 

Default

Restoring Factory Defaults on the Dew Point Controller

1.Make sure jumper setting for input type is set for Current Input (I), right jumper.

2.Return controller to housing.

3.Press the Display button for one (1) second to enter Menu Display.

4.Press the Arrow Up button to switch between menus.

5.To switch parameters within a menu, press Up Arrow button.

Figure 9

Setting List for Dew Point Controller, Part No. A0548567

Mode

Parameter

Setting range

Default

Factory

 

 

 

 

setting

Protect

SECr Security

0 to 6

1

3

Protect

YEYP A/M Key Protect

ON/OFF

OFF

ON

Manual

Manual MV

-5.0 to 105.0 %

0.0

Default

Level 0

SP Set Point

SP lower limit to upper limit EU

0

Default

Level 0

r-S Run/Stop

Run/Stop

Run

Default

Level 1

AL-1 Alarm Value 1

-1999 to 9999 EU

0

-10.0°F/-23°C

Level 1

AL-2 Alarm Value 2

-1999 to 9999 EU

0

-10.0°F/-23°C

Level 1

C-db Dead Band

-19.99 to 99.99%FS

0.00

Default

Level 1

HYS Hysteresis (Heat)

0.01 to 99.99% FS

0.10

Default

Level 1

CHYS Hysteresis (Cool)

0.01 to 99.99 FS

0.10

Default

Level 2

SPrU Sp Ramp Time Unit

M(Minutes)/H(Hours)

M

Default

Level 2

SPrt Sp Ramp Set Value

0 to 9999 EU

0

Default

Level 2

CnF Input Digital Filter

0 to 9999 SEC

0

Default

Level 2

ALH1 Alarm 1 Hysteresis

0.01 to 99.99%

0.02

Default

Level 2

ALH2 Alarm 2 Hysteresis

0.01 to 99.99%

0.02

Default

Level 2

Cn5H input shift upper limit

-199.9 to 999.9°C

0.0

Default

Cabinet Series Dehumidifying Dryer

46

Page 46
Image 46
Sterling Plumbing 90 Option Type, RE232C, RS-485, Event Input, Transfer Output, Mode, Parameter, Setting range, Factory