Sterling Plumbing Cabinet Series Dehumidifying Dryer 4-2Process Air Dew Point Display, OUT1, OUT2

Models: 100 150 90 Cabinet Series Dehumidifying Dryer 225

1 52
Download 52 pages 20.74 Kb
Page 19
Image 19

4-2 Process Air Dew Point Display

The Dew Point display indicates the current process air delivery moisture content. The display uses a microprocessor-based controller for reading dew point air temperature. The controller is a modular, self-contained removable unit in the mounting housing. All parameters are factory-set and adjusted; no field adjustment to the internal controls is necessary. The high dew point alarm is also factory adjusted.

4-3 Process Air Temperature Controller

Our dehumidifying dryers use a microprocessor-based PID temperature controller for maintaining process air temperature. The controller is a modular, self-contained unit you can remove from the mounting housing. All parameters except for the process air set point is factory set and adjusted; no field adjustment to the internal controls is necessary.

4-4 Identifying Temperature Controller LED Indicators

LED

Description

Indicator

 

 

 

Process Value

During normal operation, the process value (PV)

Numerical

numeric LED indicator displays the process

LED

temperature at the To Process thermocouple. It

 

also lists parameters during setup and error

 

messages if any errors occur.

 

 

Set Value

During normal operation, the set value (SV)

Numeric LED

numeric LED indicator displays the process set

 

point you selected for the dryer. The dryer then

 

maintains this set point temperature. This LED

 

indicator also displays parameter and pre-set

 

function values during setup.

 

 

OUT1

Lit when control output 1 turns on. The Out

 

indicator lights when the controller signals the

 

process heaters to be energized.

 

 

OUT2

Lit when control output 2 turns on. Not used in

 

this application.

 

 

MANU

Lit when the manual operation mode is being

 

used.

 

 

STOP

Lit when control operation has been stopped. Not

 

used in this application.

 

 

RMT

Lit during remote operation. Not used in this

 

application.

 

 

AT

Flashes during auto-tuning.

 

 

SUB1

Lit when the output function assigned to auxiliary

 

output 1 turns on.

 

 

Cabinet Series Dehumidifying Dryer

19

Page 19
Image 19
Sterling Plumbing Cabinet Series Dehumidifying Dryer 4-2Process Air Dew Point Display, OUT1, OUT2, Manu, Stop, Numerical