4-6 Setting the Process Air Temperature

To change the process air temperature set point with the dryer running:

„Press the Up Arrow button to increase the set point to the temperature you want.

„Press the Down Arrow button to lower the set point to the temperature you want.

„Press the Auto-tune button to initiate auto-tuning.

4-7 PLC Controller

The PLC controller uses an Allen-Bradley programmable logic controller (PLC). This “brick”- type controller has 32 I/O points: twenty (20) inputs and twelve (12) outputs, all inputs and outputs are 115 VAC.

All programming and logic is factory-installed on an EEPROM chip and cannot be modified. A battery backup retains programming if power fails. Battery life is five (5) years at room temperature.

If the alarm indicator blinks intermittently, replace the battery within one week.