Chapter 2: General Information
2-1 Models Covered
This manual provides instructions for installing and operating 90, 100, 150, and 225 CFM
2-2 Equipment Function
Our dehumidifying dryers are designed to generate heated, dehumidified air at carefully controlled temperatures for use in
2-3 Necessary Documents
The documents listed below are necessary for the operation, installation, and maintenance of Cabinet Series dehumidifying dryers. You can obtain additional copies from the manufacturer.
Make sure that the appropriate personnel are familiar with these documents:
;This manual.
;The schematic and assembly drawings included in the customer information packet.
;The Customer Parts List included in the information packet.
;Operation and installation manuals for any optional controls or auxiliary equipment in the drying system.
2-4 Standard Features
;Rugged compact frame with handle and sturdy 4” (10 cm) casters.
;Dual blower dryer with dual desiccant beds and
;Up to 400ºF (204ºC) drying temperature range.
;Cartridge type (two stage) air filters for all blowers.
;Integral Control Center for dryer options.
;Electrical disconnect with all wiring to a common terminal point.
;PLC microprocessor control of the drying and conveying stations.
;Digital Dew Point monitor indicates dryer efficiency.
;Sequence shutdown of the dryer.
2-5 Options
Options can tailor your dehumidifying dryer system to meet the exact requirements of the drying task being performed.
;13X desiccant.
;Aftercoolers for high and low temperature applications.
;
Cabinet Series Dehumidifying Dryer | 11 |