Level 2 | Cn5L input shift lower limit |
| 0.0 | Default | |||
|
|
|
|
| |||
Mode | Parameter | Setting range | Default | Factory | |||
|
|
|
|
|
| setting | |
Setup | 0 to 21 | 2 | 17 | ||||
Setup | Scaling Lower Limit +1 to | ||||||
9999 EU | |||||||
|
|
|
|
|
| ||
Setup | 0 | ||||||
Limit | |||||||
|
|
|
|
|
| ||
Setup | dP Decimal Point | 0 to 3 | 0 | Default | |||
Setup | CnCE Parameter Initialize | Yes/No | No | Default | |||
Setup | 6Ut1 Control Output 1 | Heat/Cool/Alarm 1/Alarm 2/ | Heat | COOL | |||
Assignment | Alarm 3/LBA | ||||||
|
|
|
| ||||
Setup | 6Ut2 Control Output 2 | Heat/Cool/Alarm 1/Alarm 2/ | Default | ||||
Assignment | Alarm 3/LBA | ||||||
|
|
|
| ||||
SetUp | Sub 1 Auxiliary Output 1 | Alarm 1/Alm 2/Alm 3/LBA/S. | Default | ||||
Assignment | ERR/E333 | ||||||
|
|
|
| ||||
Setup | ALt1 Alarm 1 Type | 0 to 11 | 2 | 8 | |||
Setup | AL1n Alarm 1 open in alarm | NO/NC | NO | Default | |||
Setup | ALt2 Alarm 2 Type | 0 to 11 | 2 | 8 | |||
Setup | AL2n Alarm 2 open in alarm | NO/NC | NO | Default | |||
Setup | 6rEU Direct/Reverse | Default | |||||
Operation | |||||||
|
|
|
|
| |||
Expansion | SP Lower Limit +1 to | 1300 | |||||
Scaling Upper Limit | |||||||
|
|
|
|
|
| ||
Expansion | Scaling Upper Limit to Sp | ||||||
Lower Limit | |||||||
|
|
|
|
|
| ||
Expansion | CntL PID/ON/OFF | PID | |||||
Expansion | rESt Standby Sequence | 0/1 | 0 | Default | |||
|
| Reset Setting Method |
|
|
| ||
Expansion | rEt Automatic Return of | 0 to 99 SEC | 0 | Default | |||
|
| Display Mode |
|
|
|
If preset parameters on the controller have been tampered with and it no longer properly controls temperature and displays dew point, you can restore the controller to factory setup.
Cabinet Series Dehumidifying Dryer | 47 |