INSTALLATION INSTRUCTIONS
6a. FIREGRATE REMOVAL (riva)
6a.1 To remove grate:
•First remove the centre grate by tipping the grate control boss downwards and lifting the centre grate vertically
8
PR7250
6a.2 The main grate can then be lifted by the front first and then rotating the main grate to clear the firebox.
9
PR7241
6a.3 Ensure that the seal tape on the underside of the grate is in good condition and correctly fitted. If not, replace with new. (Stovax part number 4998)
10
Seal Tape
PR7061
6a.4 Replace the grate in the reverse order from removal.
6a.5 The grate must sit flat on the side supports, with no debris trapped under it. Check that the centre grate sits flat and rotates freely with no debris trapped under it.
6b. FIREGRATE REMOVAL (riva avanti)
(Tools required – None)
6b.1 To remove the firegrate first remove the centre grate:
•Disconnect the operating linkage from the grate
•Move the Primary air control to the fully open position
•Spring the operating link forward to disconnect the balljoint
The centre grate can then be lifted out from inside of the firebox.
11
6b.2 The main grate can then be lifted out of the firebox.
6b.3 Replace the grate system in the reverse order from removal.
6b.4 Ensure that the seal tape on the underside of the grate is in good condition and correctly fitted. If not replace with new. (Stovax part number 4998)
12
Seal Tape
PR7061
6b.5 The grate must sit flat on the side supports, with no debris trapped under it. Check that the centre grate sits flat and rotates freely with no debris trapped under it.
24