INSTALLATION INSTRUCTIONS
8.2The removal of the frame is the reverse of the previous operations.
8.3Protect the Riva MF paintwork from possible damage and marking from building debris during installation.
9. FITTING CONVECTION AIR DUCTS
Riva 55/66/66 Avanti/76 Only
Convection air may be ducted from the Riva MF to distribute warm air to other parts of the building. The distance this air may be ducted, and the position of the ducts will depend on the layout of the property.
A convection air ducting kit can be purchased from your Stovax dealer (Stovax part number 8572), as shown in diagram 18.
18
Wall plate
Vent
Duct
Clamp Band
Duct Spigot
Cover (Remove from box)
9.1To fit the ducts:
•Remove the cover plates on the top of the firebox, by drilling out the fixing rivets
•Fit the duct spigots with either pop rivets or
•Fit and seal ducting to the spigots
9.2Due to the high temperature of the ducts combustible material must be placed no closer than 100mm to the surface. The duct exits and grills must only be placed in a
9.3Protect or place the exit ducts at a high level, as the grill surfaces become very hot when in use.
Use a suitable guard if the exit is at low level to prevent touching or obstruction. Do not place combustible items near the operating duct exit as conducted and radiated heat could cause a fire hazard.
9.4Following completion of the fitting of the ducts replace and finish the final 300mm of masonry above the front of the Riva MF. See diagram 20.
19
HOT
Final Masonry
300mm