USER INSTRUCTIONS

USER INSTRUCTIONS

1.General POINTS

1.1Before use of this appliance please read these instructions fully.

1.2All local regulations, including those referring to national and European Standards need to be complied with when installing the appliance.

1.3Only use for domestic heating in accordance with these operating instructions.

1.4You must burn only approved fuels. Do not use with liquid fuels or as an incinerator.

1.5Appliance surfaces become very hot when in use. Use a suitable fireguard if young children, elderly or infirm persons are present.

Stovax offer firescreens, sparkguards and hearthgate systems for protection*. Your Stovax dealer can advise you about these products.

1.6Do not place photographs, TV’s, paintings, porcelain or other combustible items on the wall or near the appliance. Exposure to hot temperatures will cause damage.

1.7Extractor fans or cooker hoods must not be placed in the same room or space as this can cause appliance to emit fumes into the room.

1.8Do not obstruct inside or outside ventilation required for the safe use of this appliance.

1.9Do not make unauthorised changes to the appliance.

1.10The chimney must be swept at least once a year. See Section 12

1.11Do not connect, or share, the same flue or chimney system with another appliance.

SERIAL NUMBER

1.12This number is required when ordering spare parts or making warranty claims.

It is found as shown.

 

PRODUCT:

 

MODEL No.

Riva

SERIAL No.

PR7029

 

PRODUCT:

MODEL No.

SERIAL No.

Riva Avanti

AIR CONTROLS

Cleanburn Technology and Convector Efficiency

Riva appliances incorporate the latest cleanburn technology with a unique 'Opti-Burn' setting in order to burn fuels with greater efficiency.

See Diagram 3.

1)Primary Air - burns the fuel under the fuel bed. For use with solid fuel and initially with wood fires.

2)Airwash - air drawn over the window cleans the glass. The source of Primary Combustion air when burning wood.

3)Unique 'Opti-Burn' setting provides optimum efficiency and visual effect.