5.BAFFLE REMOVAL (all)

INSTALLATION INSTRUCTIONS

5

Remove the fixing screws and lift the ashpit door clear of the appliance

4.2The replacement of the system is the reverse of the previous operations.

5.BAFFLE REMOVAL (all)

(Tools required – None)

The Riva MF is fitted with a twin baffle system, consisting of upper and lower baffles, Diagram 6.

6

Upper Baffle

Lower Baffle

PR7017

5.1Remove the log guard from the Riva MF to give access to the firebox.

5.2First remove the Lower Baffle, see diagram 7:

Lift the front edge to unhook it from the support bars

Pull the baffle forward to disengage the rear edge from the location above air inlet holes

Rotate the baffle to remove from the firebox through the door opening

5.3Second remove the Upper Baffle, see diagram 8:

• Pull forward to disengage it from the hanging points at the top of the firebox

7

Rotate the baffle to remove from the firebox through the door opening

8

5.4The replacement of the system is the reverse of the previous operations.

5.5Do not modify the baffle