USER INSTRUCTIONS
7. ASH REMOVAL
7.1All fuels:
• Open Ash pan Cover (Riva 66 only), See Diagram 8
8
Ashpan Cover
Riva
9
Riva Avanti | PR7051 |
|
•Remove Ashpan carefully. Heat can remain long after use
•Use gloves, or place the ash into a Stovax Ash Caddy
(Stovax Part No. 4227)
•Remove ash at least once every week
•Do not place hot ash in a bin made from plastic or any other combustible material.
8.Over night burning
8.1It is possible to get the appliance to burn over night. In order to do this:
•
•Set air controls to low combustion settings
This will blacken the glass over night but it will clear when operated at high output for a short period.
•Use smokeless fuel or small, thick logs depending on fuel desired
9.OVER-FIRING
9.1Do not
•Close the air controls to reduce the output
9.2
10.Chimney fire
10.1If a chimney fire occurs:
•Shut all air controls immediately
•Evacuate the building
•Call the fire brigade
•Do not
10.2Do not use the appliance after a chimney fire until: a) It has been inspected by a registered installer, confirming the appliance is safe to use*
b) The chimney system inspected and swept by a chimney sweep, confirming the system is structurally sound and free from obstruction before
c) It is repaired as required before
11.GENERAL CLEANING
11.1Allow appliance to cool thoroughly to avoid risk of burns:
•Clean regularly, according to the level of use
•Give attention to the baffle system, flue ways and removing ash
Regular cleaning and maintenance will help give many years of safe use.
To refresh painted finishes use Stovax Thermolac paint.
•Clean finishes using warm soapy water and a soft clean cloth
•Do not use aerosol sprays near an operating appliance
Wipe dry with a soft clean cloth before
In the U.K:
*registered with HETAS (GB only)/INFO (Republic of Ireland only)
**This should be done by a NACS registered (UK only)/ INFO registered (Eire only) chimney sweep, who will issue you with a certificate.
10