2. USING ELECTRIC POWER | NOTE |
■ Check the voltmeter for proper voltage. | If no generating condition is found out, |
(approx.120V). | please consult nearest ROBIN dealer. |
| |
|
|
WARNING
■Make sure that the appliance is switched OFF before connecting it to the generator.
■Do not move the generator while it is running.
■Be sure to ground the generator if the connected appliance is grounded. Failure to ground unit may lead to electrical shock.
FRANÇAISE
ESPAÑOL
(1) AC APPLICATION (See Fig. 4-q,w)
(a)Check the voltmeter for proper voltage. (approx.120V).
■This generator is thoroughly tested and adjusted in the factory.
If the generator does not produce the specified voltage, consult your nearest Robin dealer or service shop.
(b)Turn off the switch(es) of the electrical appliance(s) before connecting to the generator.
(c)Insert the plug(s) of the electrical appliance(s) into the receptacle. (See Fig.
■Check the amperage of the receptacles used referring to TABLE 1, and be sure not to take a current exceeding the specified amperage.
■Be sure that the total wattage of all appliances dose not exceed the rated output of the generator.
(d)Turn the AC circuit breaker to the position ON. (See Fig.
Style | Ampere Receptacle | AC plug | Description | |
| Up to 20A | NEMA | NEMA | GFCI (Ground Fault |
| Circuit Interrupter) | |||
| ||||
|
| Receptacle, duplex | ||
|
|
|
| |
| Up to 30A | NEMA | NEMA | Locking Receptacle |
| ||||
|
|
| ||
| Up to 20A | NEMA | NEMA | Locking Receptacle |
| ||||
|
|
|
TABLE 1
WARNING
■To take power out from the TWIST LOCK RECEPTACLE, insert the plug into the receptacle, and turn it clockwise to the lock position. (See Fig.
■Be sure to ground the generator if the connected electrical device is grounded.
10