All diesel fuels which satisfy the following

 

 

ENGLISH

 

specifications are suitable:

 

 

 

ASTM D 975 - 1D / 2D

 

 

 

 

EN 590 or

 

 

 

 

BS 2869 A1 / A2 or

 

 

 

 

Remove fuel tank cap.

 

 

 

 

Before the first start or if the fuel tank has been

 

 

 

run dry, completely fill the fuel tank with diesel.

 

 

 

The bleeding of the fuel system is automatically.

 

 

 

 

 

 

 

 

 

 

Fuel tank capacity :

(L)

 

 

 

 

 

 

 

 

 

RGD3300H . . . . . . . . . . . . . . . . .

12.0

 

FRANÇAISE

 

 

RGD5000H . . . . . . . . . . . . . . . . .

12.0

 

 

 

 

 

 

 

NOTE

 

 

 

 

 

 

 

 

If a double fuel filter system is provided ,

 

 

wait for a short time after replenishing fuel

 

 

(approx. 1 to 2 minutes) for automatic

 

 

bleeding to be completed.

 

 

 

 

 

 

 

 

Close and fix fuel tank cap.

At temperatures below 0 °C, winter-grade fuel should be used or paraffin added to the fuel well in advance.

ESPAÑOL

Lowest ambient temperature

Paraffin content for:

 

 

when starting, in °C

Summer fuel

Winter fuel

 

0

up to

-10

20 %

 

-10

up to

-15

30 %

 

-15

up to

-20

50 %

20 %

 

-20

up to

-30

50 %

Wipe off any spilled fuel before starting the engine.(See Fig. 2-r)

WARNING

Make sure you review each warning in order to prevent fire hazard.

Do not refill tank while engine is running or hot.

Close fuel cock before refueling with fuel.

Be careful not to admit dust, dirt, water or other foreign objects Into fuel.

Wipe off spilt fuel thoroughly before starting engine.

Keep open flames away.

3. CHECKING COMPONENT PARTS

Check following items before starting engine:

Fuel leakage from fuel hose, etc.

Bolts and nuts for looseness.

Components for damage or breakage.

Generator not resting on or against any adjacent wiring.

4.CHECK GENERATOR SURROUNDINGS.

WARNING

Make sure you review each warning in order to prevent fire hazard.

Keep area clear of in flammables or other hazardous materials.

Keep generator at least 3 feet (1 meter) away from buildings or other structures.

Only operate generator in a dry, well ventilated area.

Keep exhaust pipe clear of foreign objects.

Keep generator away from open flame. No smoking!

Keep generator on a stable and level surface.

Do not block generator air vents with paper or other material.

5.GROUNDING THE GENERATOR

To ground the generator to the earth, connect the grounding lug of the generator to the grounding spike driven into the earth or to the conductor which has been already grounded to the earth. (See Fig. 2-t)

q GROUNDING SPIKE

If such grounding conductor or grounding electrode is unavailable, connect the grounding lug of the generator to the grounding terminal of the using electric tool or appliance. (See Fig. 2-y)

q GROUND TERMINAL

6