MAINTENANCE
DAILY INSPECTION
Before running the generator, check the following service items:
Clean air cleaner element
Leakage of fuel and engine oil
Enough clean engine oil
AC and DC terminals for damage
Enough fuel
Excessive vibration,noise
Safe surroundings
Loose or broken bolts and nuts
PERIODIC MAINTENANCE
Periodic maintenance is vital to safe and efficient operation of your generator.
Check the table below for periodic maintenance intervals.
WARNING
Only carry out maintenance work with the engine switched off.
Observe all relevant laws and regulations governing the handling and disposal of used oil, filters and cleaning agents.
Protect the starting key against unauthorised use.
On engines with an electric starter, disconnect the battery's negative terminal.
When maintenance work has been completed, check that all tools have been removed from the engine and all protective guards fitted again.
Before starting the engine, ensure that there are no persons in the danger area close to the engine or equipment.
Maintenance chart (ENGINE)
| Maintenance interval | Maintenance work required | |
|
|
| |
| Every 8 - 15 | Check oil level. | |
operating hours, | |||
or before each | Check combustion and cooling air intake zone. | ||
| |||
| daily |
| |
|
|
| |
|
| Change engine oil. | |
250 | Every 250 | Check and adjust valve clearances. | |
Clean cooling air area. | |||
operating hours | |||
| Check screw connections. | ||
|
| ||
|
| Clean mesh insert for exhaust. | |
|
|
| |
500 | Every 500 | Change fuel filter element. | |
operating hours | |||
| |||
|
|
| |
1000 | Every 1000 | Clean the oil filter. | |
operating hours | |||
|
|
ENGLISH
FRANÇAISE
ESPAÑOL
15