Sun Microsystems 6U manual Remove the wrist strap from the chassis and from your wrist

Models: 6U

1 106
Download 106 pages 54.73 Kb
Page 52
Image 52
Manual background

The hot-swapLED shows whether the adapter has been activated.

If the hot-swap LED is OFF (unlit), the I/O slots in the server have been set to full hot swap and the adapter has been activated. Go to Step 15.

If the hot-swap LED is ON, then the I/O slots in the server have been set to basic hot swap. You must use software commands to activate the I/O card. Go to Step 11.

Note You should also use the hot-swap LEDs on the server when installing the adapter. For example, Netra ct servers contain an OK to Remove LED ( Manual backgroundManual background) on the system status panel that is used like the hot-swap LED on this adapter. Refer to your system’s service manual for a description on how the hot-swap LEDs are used during a hot-swap installation.

11.Remove the wrist strap from the chassis and from your wrist.

12.Log in to the server.

Refer to the server’s documentation for the procedure.

13.At the terminal prompt, type the hot-swap software commands to identify and attach the adapter to the server.

These commands may be specific to the server’s hot-swap software. Refer to the server’s documentation for the correct commands and procedures.

For example, if you are installing the adapter into a Netra ct server, you would use the cfgadm pci command to list the attachment point IDs in the server. On a Netra ct 800 server, you should see feedback similar to the following:

# cfgadm pci

 

 

 

 

Ap_Id

Type

Receptacle

Occupant

Condition

pci_pci0:cpci_slot2

unknown

empty

unconfigured

unknown

pci_pci0:cpci_slot3

stpcipci/fhs

connected

configured

ok

pci_pci0:cpci_slot4

stpcipci/fhs

connected

configured

ok

pci_pci0:cpci_slot5

unknown

empty

unconfigured

unknown

pci_pci0:cpci_slot6

unknown

empty

unconfigured

unknown

pci_pci0:cpci_slot7

unknown

empty

unconfigured

unknown

pci_pci0:cpci_slot8

stpcipci/fhs

connected

configured

ok

 

 

 

 

 

Once you have identified the attachment point ID on the Netra ct server, you can use the following commands to attach the adapter to the server:

#cfgadm -c connect attachment-point-id

#cfgadm -c configure attachment-point-id

34 Sun Quad FastEthernet 6U CompactPCI Adapter Installation and User’s Guide • June 2000

Page 52
Image 52
Sun Microsystems 6U manual Remove the wrist strap from the chassis and from your wrist, Log in to the server