Sun Microsystems 6U manual Installing the Front-Access Adapter in Hot-Swap Mode

Models: 6U

1 106
Download 106 pages 54.73 Kb
Page 47
Image 47
Installing the Front-Access Adapter in Hot-Swap Mode

Determining the Installation Type

You can install the adapter in the system in either a hot-swap mode or in a cold- swap mode. (See “Installation Methods” on page 4 for more information.)

Hot swap—see “Installing the Front-Access Adapter in Hot-Swap Mode” on page 29 for the procedure.

Cold swap—see “Installing the Front-Access Adapter in Cold-Swap Mode” on page 36 for the procedure.

After installing the adapter, see “Connecting the Cables to the Front-Access Adapter” on page 40 for instructions on connecting the cables.

Installing the Front-Access Adapter in Hot-Swap Mode

When installing the adapter in a server in hot-swap mode, you must consult the documentation that shipped with the server. The server’s documentation will describe the hot-swap commands and system LEDs that will be used when installing the adapter.

Caution Do not use excessive force when installing the adapter into the CompactPCI slot. You may damage the adapter’s connector or the pins on the midplane, causing permanent damage to the adapter or to the system. If the adapter does not seat properly when you apply even pressure, remove the adapter and carefully reinstall it.

To Install the Front-Access Adapter in Hot-Swap

Mode

The adapter is hot-swap aware, which means the system will recognize the adapter during the installation.

1.Retrieve the wrist strap from the adapter’s ship kit.

2.Attach the adhesive copper strip of the antistatic wrist strap to the metal chassis of the system. Wrap the other end twice around your wrist, with the adhesive side against your skin.

3.Locate the slot where you will install the adapter.

Chapter 3 Installing the Front-Access Adapter 29

Page 47
Image 47
Sun Microsystems 6U manual Installing the Front-Access Adapter in Hot-Swap Mode, Determining the Installation Type