Be sure that system pressure is relieved and disabled before proceeding.

FIG. 11: HydraCheck Installation - Fixed Ratio Base

NOTE: The HydraCheck kit is intended to be used with

Install HydraCheck Shock

low viscosity materials to minimize splashing. It is not

6.

Install the shock absorber through the opening in

intended to be used as a timer or flow control device.

 

the pump sub-assembly with the groove for the snap

 

 

 

 

Prepare Machine for Kit Installation

 

 

ring on the back of the pump assembly. The shock

 

 

absorber can be inserted through the front.

 

 

 

 

1.

Navigate to the Maintenance screen.

 

7.

Install the shock snap ring (included with shock, not

 

 

 

2.

Press the Retract Piston button (

).

 

shown) onto the shock absorber in the groove far-

 

thest from the pump sub-assembly.

3.

Relieve system pressure. See Pressure Relief Pro-

8.

Install set screw and torque to 85 in-lb (9.6 N•m).

 

cedure, page 33.

 

 

 

4.Loosen the machine shield screws.

5.Remove the machine shield.