Maintenance

Maintenance

Schedule

Action

Schedule

Procedure

 

 

 

 

Check Water/Air Separator

Daily before use

1.

Check water/air separator for water.

(Not provided)

 

2.

Open valve at base of water/air separator to purge

 

 

 

water.

 

 

 

 

Check Desiccant Dryer (only

Daily before use

1.

Check the color of the desiccant

installed if chemical is moisture

 

2.

Replace as required.

sensitive)

 

 

 

 

 

 

 

Check Tanks

Daily before use

1.

Check material levels and refill as necessary.

 

 

2.

Verify the material reservoirs are vented properly.

 

 

 

Check Dispensing Ratio

Daily before use or as

See Phasing Adjustment page 29.

 

required

 

 

 

 

 

Clean Pump Shafts

Daily after shutdown

See Clean the Pump Shafts on this page.

 

 

 

Clean Dispense Head

Daily

See Shutdown on page 34.

 

 

 

Disassemble and Clean Dispense

As required

See Disassemble and Clean the Dispense Head on

Head

 

this page.

 

 

 

Upgrade LCM

As required

See Install Upgrade Token on page 36

 

 

 

 

Clean the Pump Shafts

1.Close the vented ball valve at the left, rear of the machine.

2.Press the Machine Disable Mode key ( ).

3.Push the piston block to the fully retracted position.

4.Clean both pump shafts with a compatible solvent and lubricate with mesamoll, silicon oil, or other compatible lubricant.

Disassemble and Clean the Dispense Head

1.Relieve pressure. See Pressure Relief Procedure, page 33.

2.Remove the dispense head from machine.

3.Dismantle the dispense head. See MD2 Dispense Valve manual referenced at the beginning of this manual.

4.Clean all parts.

5.Lubricate all parts with a thin coat of mesamoll, sili- con oil, or compatible lubricant.

6.Reassemble the dispense head.

7.Reinstall the dispense head on machine.

334135B

35

Page 35
Image 35
Graco 334135B Maintenance, Schedule, Clean the Pump Shafts, Disassemble and Clean the Dispense Head