Graco 334135B LCM Error Codes, Trigger, Name, Type, Causes, Fixes, Condition

Models: 334135B

1 70
Download 70 pages 11.01 Kb
Page 39
Image 39
LCM Error Codes

Troubleshooting

LCM Error Codes

If an error condition exists, the front Panel LED will blink the number of times corresponding to the error code number, pause, then repeat. After the user acknowledges the generated error screen, the error number will appear on the bot- tom left-hand side of the main run screen, and the described blink sequence will continue. If more than one error is present, all will be presented, separated by commas. When the condition is cleared, the corresponding error number will be removed from the main run screen. If an error code is present, the machine will not dispense.

 

 

 

 

 

Trigger

Code

Name

Type

Causes

Fixes

Condition

 

 

 

 

 

 

E3

Improper

Alarm

Machine has not been

Perform pump position

When

 

Machine Cali-

 

calibrated or has been

entries in Position Calibra-

requesting a

 

bration

 

calibrated incorrectly.

tion Screen. Retract posi-

dispense

 

 

 

 

tion must be less than

operation.

 

 

 

 

metering tube position, which

 

 

 

 

 

should be less than the fully

 

 

 

 

 

extend position.

 

 

 

 

 

 

 

E4

Bad Linear

Alarm

1. Connection to position

1. Verify connections to the

Invalid read-

 

Position Sen-

 

sensor disconnected.

sensor.

ings from the

 

sor

 

 

 

sensor.

 

 

 

2. Power to position sen-

2. Verify proper readings from

 

 

 

 

sor interrupted.

sensor on setup screen 1.

 

 

 

 

3. Bad position sensor.

3. Replace sensor

 

 

 

 

 

 

 

E5

Stuck key

Alarm

1. Key is in an active

Replace LCM Module.

If key is

 

 

 

state.

 

detected to

 

 

 

 

 

be active for

 

 

 

2. Tactile switch on LCM

 

more than 30

 

 

 

is shorted or broke.

 

seconds.

 

 

 

 

 

 

334135B

39

Page 39
Image 39
Graco 334135B LCM Error Codes, Trigger, Name, Type, Causes, Fixes, Condition, entries in Position Calibra