Appendix C - LCM Setup Screen Overview

Appendix C - LCM Setup Screen Overview

Password Entry Screen

Open Dispense Valve Position Calibration

 

Screen

If a password is programmed into the LCM, the user will be prompted to enter a password. If no password has been entered (all 0's on the password set/ clear setup screen), this screen will be bypassed.

This screen is to set or view the position with reference to the metering tube entrance where the dispense valve is opened during the forward stoke of the pump.

Position Calibration Screen

Dispense Amount Prohibit and View Cycle

 

Counter Screen

This screens is used to set or observe the proper posi- tions on the linear position sensor for full extend, retract and entrance into the metering tube. All valid entries must be present for the machine to operate. The extend position must be greater than the metering tube posi- tion, which must be greater than the retract position. When the position is accepted, the real time position sensor reading in the middle of the screen will be trans- ferred to above the graphic for the corresponding posi- tion. The process needs repeated for all three positions.

Phasing Shot Calibration Screen

This screen is to instigate a phasing shot, and to define the percentage of stroke for a phasing shot.

This screen will enable the user to lock out or enable the operator to change stroke percentage for the shot mode run screen. The user will also be able to view the machine cycle counter.

Setup Screen Password Set/Clear Screen

This screen will allow the user to view, set or clear (by entering four 0's) the password. Setting a new password or clearing the password feature is identical to the method used to enter the setup screen, if a non-zero password is present.