Operation

Startup

1.Locate the power switch at rear of machine and turn the power on. The display module will automatically turn on and begin to load.

2.Open the vented ball valve (not provided).

3.If the machine is in Disabled Mode, press the Power

On button ( ) to exit Disabled mode and to select a new operating mode. Press the Enter but-

ton ( ) to accept the new operating mode.

FIG. 9: Disabled Mode

Operation

Pressure Relief

Procedure

Follow the Pressure Relief Procedure whenever you see this symbol.

This equipment stays pressurized until pressure is manually relieved. To help prevent serious injury from pressurized fluid, such as skin injection, splashing fluid and moving parts, follow the Pressure Relief Procedure when you stop spraying and before cleaning, checking, or servicing the equipment.

1.Place a waste container below the dispense valve.

2.Navigate to the Maintenance Mode Run Screen.

3.Press the Shot Mode Designation button ( ) on the Maintenance Mode Run Screen to relieve chemical pressure. Press the Shot Mode Designa-

tion button ( ) again to close the dispense valve.

4.Press the Machine Disable Mode button ( ).

5.Close the vented ball valve.

334135B

33

Page 33
Image 33
Graco 334135B Operation, Startup, Pressure Relief Procedure, Navigate to the Maintenance Mode Run Screen