Graco 334135B important safety instructions Troubleshooting, Problem, Cause, Solution

Models: 334135B

1 70
Download 70 pages 11.01 Kb
Page 37
Image 37
Troubleshooting

Troubleshooting

Troubleshooting

Before starting any troubleshooting procedures, perform the following procedure.

1.Relieve pressure. See Pressure Relief Procedure, page 33.

2.Disconnect AC power from the machine.

3.Allow the machine to cool if the machine has a heat control option.

Try the recommended solutions in the order given for each problem to avoid unnecessary repairs. Verify all circuit breakers, switches, and controls are properly set and wiring is correct.

Problem

Cause

Solution

 

 

 

 

 

 

Display Module completely dark

No power

Verify cable is plugged in.

 

 

 

 

 

Verify rear AC Power switch is ON.

 

 

 

 

Loose connection

Tighten all cables on Display Module.

 

 

 

 

Bad display module

Replace Display Module.

 

 

 

No or incorrect amount of material

Tank empty

Fill tank with material.

dispensed from either side.

 

 

Tank clogged

Verify no obstruction in the tank.

 

 

 

 

 

Air in material

Prime the machine until the air is

 

 

removed.

 

 

 

 

Check valve malfunction

Remove; clean or replace check

 

 

valve.

 

 

 

 

Piston worn or broken

Remove and replace piston if worn.

 

 

 

Piston stalled

Input air reduced or removed

Reconnect input air line to machine.

 

 

Increase air pressure regulator

 

 

adjustment.

 

 

 

 

Mixer blocked

Replace static mixer.

 

 

 

 

Open Dispense Valve (ODV) adjust-

Readjust the ODV setting to occur

 

ment too late

sooner.

 

 

 

 

Blocked check valve

Remove check valve; clean and

 

 

replace.

 

 

 

 

Air cylinder failure

Remove air cylinder and reinstall air

 

 

cylinder parts as necessary.

 

 

 

Significant material leaking from

Pump shaft worn and/or shaft seal

Remove pump shaft assembly, and

pump rear seal

worn

reinstall rear pump rebuild kit.

 

 

 

Material dispensed not correct vol-

Machine air pressure has changed

Readjust air pressure regulator to

ume

since calibration.

value used when machine was cali-

 

 

brated, or recalibrate machine.

 

 

 

 

Not enough material in one or more

Check tank levels; fill and prime as

 

tanks

necessary.

 

 

 

 

Mixer has slight obstruction

Replace static mixer. Prime machine.

 

 

 

 

Check valve malfunction

Remove check valve; clean or

 

 

replace as necessary.

 

 

 

 

Piston worn or broken

Replace piston.

 

 

 

334135B

37

Page 37
Image 37
Graco 334135B Troubleshooting, Problem, Cause, Solution, Relieve pressure. See Pressure Relief Procedure, page