Error Message

 

Corrective Action

 

 

 

cfgadm: Library error: Failed to get Fabric device

The operation to get Fibre Channel device list on a host

list

 

port failed. Check the condition field of the host port

 

 

 

from the cfgadm listing and diagnose the Fiber

 

 

 

connection of the host port.

 

 

 

cfgadm: Library error: failed to create device

The configure operation failed on the device node with

node: errno text

 

error specified in errno text. Check the condition field

 

 

 

of the device from the cfgadm -lalisting and diagnose

 

 

 

the Fabric connection of the device.

 

 

 

cfgadm: Library error: failed to offline: device

Unmount the file system listed in the error message and

path

 

try the cfgadm operation again.

Resource

Information

 

------------------ --------------------------

 

/dev/dsk/c1t0d0s0

mounted filesystem

 

"/file-system"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fabric Display Error Messages

TABLE B-2Fabric Display Messages

Error Message

Corrective Action

 

 

 

 

Save Operation Failed. Enter IP address and try

Verify network connection1

to Fabric and retry.

again.

 

 

 

 

 

Fabric appears to be offline. Hit REFRESH to

Verify network connection1

to Fabric and retry.

verify connection.

 

 

 

 

 

1.Verify network connection to Fabric:

Check that the correct IP address for the Fabric is entered in the Fabric Display. If the address is incorrect, then enter the correct IP address for the network switch in the Fabric.

Verify that the gateway address is correctly configured on the workstation. If the gateway is incorrect, then configure the correct gate- way.

Verify that the Fabric is accessible through the network. For example, ping the switch and verify that responses are not being dropped. If the Fabric is not accessible, then diagnose network the problem, or try to access the Fabric from a different workstation.

Try to access the Fabric from a workstation on the same subnetwork as the Fabric. If the Fabric is manageable on the same subnetwork, but is not manageable through a network gateway, then examine the network configuration (gateway address, subnet mask, etc.) on the network switch to verify that it is correct..

Examine the switch itself. Verify that the switch is powered on, and that the heartbeat LED is blinking normal ly. If the heartbeat indicates an error, then contact customer support.

146 Sun StorEdge Network FC Switch-8 and Switch-16 Installation and Configuration Guide • October 2001

Page 176
Image 176
Sun Microsystems 816-0830-12 manual Fabric Display Error Messages, Table B-2Fabric Display Messages

816-0830-12 specifications

Sun Microsystems, a major player in the development of computing hardware and software during the 1980s and 1990s, introduced various innovative products that set benchmarks for the industry. Among its range of offerings, the Sun Microsystems 816-0830-12 stands out as a notable system within its lineup. This specific model, designed primarily for server and workstation applications, showcases the combination of cutting-edge technology and robust functionality that characterized Sun's approach.

The 816-0830-12 is notable for its powerful processing capabilities, built around the SPARC architecture. This 32-bit RISC (Reduced Instruction Set Computing) design was pivotal in delivering high performance per watt, making it ideal for complex computing tasks typical in enterprise environments. The system supports multi-threading, enabling it to efficiently handle multiple operations concurrently, which is essential for server applications requiring reliability and speed.

A distinguishing feature of the 816-0830-12 is its expansive memory support. With the ability to scale up to 64 MB of RAM, it accommodates demanding applications that require significant data processing power. Additionally, it supports a variety of I/O configurations, including SCSI and Ethernet interfaces, which enhances its connectivity and versatility in networked environments.

The design of the 816-0830-12 underscores Sun Microsystems' commitment to modularity and expandability. It allows for easy upgrades and maintenance, minimizing downtime and ensuring that businesses can adapt their computing resources to evolving needs. This focus on flexibility is complemented by Sun's proprietary Solaris operating system, which offers robust security features, multitasking capabilities, and native support for networked services.

On the technological side, the 816-0830-12 incorporates features such as a built-in graphics accelerator, which enhances visual performance for graphic-intensive applications. This capability makes it suitable not only for server duties but also for environments that require workstation-like graphics performance.

In summary, the Sun Microsystems 816-0830-12 exemplifies the innovative spirit of Sun, boasting a combination of powerful processing, extensive memory options, and flexible architecture. It stands as a testament to the company's role in shaping the computing landscape, particularly in enterprise solutions, where reliability, performance, and scalability are of paramount importance.