Chapter 2 Configurations 9
Sun StorEdge A5000 and A5100 arrays are not supported.
TABLE2-2 Sun StorEdge A5200 Array
Feature Supported
Cascading No
Zone type SL zone only
Maximum number of arrays per SL zone 3
Maximum initiators per SL zone 2
Maximum initiators per array 4 (2 per loop)
Split loop support No
TABLE2-3 Sun StorEdge T3 Array and T3+ Array
Feature Supported
Cascading Yes
Zone Type nameserverzone1, SL zone
1. The host must be connected to the F-Port on the switch; Sun StorEdge T3 array must be connected to the TL port
of the switch.
Maximum number of arrays per zone 8
Maximum initiators per LUN 2
Maximum initiators per zone 22
2. This implies 2 initiators (2 hosts) for simple arrays (T3WG), but 4 initiators (2 hosts) for a partner pair (T3ES).
Each host has one path to each of the Sun StorEdge T3 arrays in the partner pair.