Chapter 2: Server Installation

Installing the Chassis Rails

Position the fi xed chassis rail sections you just removed along the side of the 6015B-Ni making sure the screw holes line up. Note that these two rails are left/right specifi c. Screw the rail securely to the side of the chassis (see Figure 2-2). Repeat this procedure for the other rail on the other side of the chassis. You will also need to attach the rail brackets when installng into a telco rack.

Locking Tabs: As you have seen, both chassis rails have a locking tab, which serves two functions. The fi rst is to lock the server into place when installed and pushed fully into the rack, which is its normal position. Secondly, these tabs also lock the server in place when fully extended from the rack. This prevents the server from coming completely out of the rack when you pull it out for servicing.

Figure 2-2. Installing Chassis Rails

Installing the Rack Rails

Determine where you want to place the SuperServer 6015B-Ni in the rack. (See Rack and Server Precautions in Section 2-3.) Position the fi xed rack rail/sliding rail guide assemblies at the desired location in the rack, keeping the sliding rail guide facing the inside of the rack. Screw the assembly securely to the rack using the brackets provided. Attach the other assembly to the other side of the rack, making sure both are at the exact same height and with the rail guides facing inward.

2-5

Page 21
Image 21
SUPER MICRO Computer 6015B-Ni manual Installing the Chassis Rails, Installing the Rack Rails