Suunto None manual Technical Data

Models: None

1 60
Download 60 pages 37.09 Kb
Page 46
Image 46

10. TECHNICAL DATA

10.1.Technical specifications Dimensions and weight:

Diameter: width 73 mm/2.85 in, length 165 mm/6.50 in

Thickness: 35 mm/1.40 in

Weight: 210 g/7.4 oz (without hose)

Depth gauge:

Temperature compensated pressure sensor

Salt water calibrated, in fresh water the readings are about 3% smaller (calibrated in compliance with EN 13319)

Maximum depth of operation: 100 m/328 ft (complying with EN 13319)

Accuracy: ± 1% of full scale or better from 0 to 80 m/262 ft at 20°C/68°F (complying with EN 13319)

Depth display range: 0 to 150 m/492 ft

Resolution: 0.1 m from 0 to 100 m/1 ft from 0 to 328 ft

Temperature display:

Resolution: 1°C/1°F

Display range: -20 to +50°C/-9 to +122°F

Accuracy: ± 2°C/± 3.6°F within 20 minutes of temperature change

Calendar clock:

Accuracy: ± 25 s/month (at 20°C/68°F)

12/24 h display

Displays only in NITROX mode:

Oxygen %: 21 - 99

Oxygen partial pressure display: 0.2 - 3.0 bar.

Oxygen Limit Fraction: 1 - 200% with 1% resolution

Logbook/dive profile memory:

Recording interval: 20 seconds adjustable (1,10,20,30,60s).

Memory capacity: approximately 42 hours of diving with 20 second recording interval

Depth accuracy: 0.3 m/1 ft

Operating conditions:

Normal altitude range: 0 to 3,000 m/10,000 ft above sea level

Operating temperature: 0°C to 40°C/32°F to 104°F

Storage temperature: -20°C to +50°C/ -4°F to +122°F

It is recommended that the instrument be stored in a dry place at room temperature.

NOTE

Do not leave the dive computer in direct sunlight!

Tissue calculation model:

Suunto Deep Stop RGBM algorithm (developed by Suunto and Bruce R. Wienke, BSc, MSc, PhD)

9 tissue compartments

Tissue compartment halftimes: 2.5, 5, 10, 20, 40, 80, 120, 240 and 480 minutes (on gassing). The off gassing halftimes are slowed down

Reduced gradient (variable) "M" values based on diving habit and dive violations. The "M" values are tracked up to 100 hours after a dive

The EAN and oxygen exposure calculations are based on recommendations by R.W. Hamilton, PhD and currently accepted exposure time limit tables and principles

Battery:

One 3 V lithium battery: CR 2450

Battery storage time (shelf life): Up to three years

Replacement: Every three years, or more often depending on dive activity

46

Page 46
Image 46
Suunto None manual Technical Data