No-decompression time limits (mins) for various depths (ft) for the first dive of a series

Depth

 

 

Personal Mode / Altitude Mode

 

 

(ft)

P0/A0

P0/A1

P0/A2

P1/A0

P1/A1

P1/A2

P2/A0

P2/A1

P2/A2

 

120

10

9

8

9

8

6

8

6

5

130

9

7

6

7

6

5

6

5

4

140

7

6

5

6

5

4

5

4

4

150

6

5

4

5

4

4

4

4

3

10.2.3. Altitude diving

The atmospheric pressure is lower at high altitudes than at sea level. After traveling to a higher altitude, you will have additional nitrogen in your body, compared to the equilibrium situation at the original altitude. This "additional" nitrogen is released gradually over time and equilibrium is restored. It is recommended that you acclimatize to a new altitude by waiting at least three hours before making a dive.

Before high-altitude diving, the instrument must be set to the Altitude Adjustment mode to adjust the calculations for the new altitude. The maximum partial pressures of nitrogen allowed by the mathematical model of the dive computer are reduced according to the lower ambient pressure.

As a result, the allowed no-decompression-stop limits are considerably reduced.

10.3. Oxygen exposure

The oxygen exposure calculations are based on currently accepted exposure time limit tables and principles. In addition to this, the dive computer uses several methods to conservatively estimate the oxygen exposure. For example:

the displayed oxygen exposure calculations are raised to the next higher percentage value

for recreational scuba diving, the recommended upper limit of 1.4 bar PO2 is used as a default

the CNS % limits up to 1.6 bar are based on 1991 NOAA Diving Manual limits

the OTU monitoring is based on the long-term daily tolerance level and the recovery rate is reduced

Oxygen related information displayed by the dive computer is also designed to ensure that all warnings and displays occur at the appropriate phases of a dive. For example, the following information will be shown before and during a dive when the computer is set in NITROX mode:

the selected O2% on the alternative display

OLF% alternative display for either CNS% or OTU% (whichever is larger)

audible alarms are given and the OLF value starts to blink when the 80% and 100% limits are exceeded

audible alarms are given and the actual PO2 value blinks when it exceeds the preset limit

in dive planning, the maximum depth according to the O2% and maximum PO2 selected