Suunto None manual Ceiling, ceiling zone, floor and decompression range, Display below the floor

Models: None

1 60
Download 60 pages 37.09 Kb
Page 30
Image 30

NOTE

WARNING

In addition, there may also be Mandatory Safety Stops which are not displayed in ASC TIME.

YOUR ACTUAL ASCENT TIME MAY BE LONGER THAN DISPLAYED BY THE INSTRUMENT! The ascent time will increase if you:

remain at depth

ascend slower than 10 m/33 ft per minute

make your decompression stop deeper than at the ceiling

These factors will also increase the amount of air required to reach the surface.

Ceiling, ceiling zone, floor and decompression range

When in decompression, it is important that you understand the meaning of ceiling, floor, and decompression range.

The ceiling is the shallowest depth to which you should ascend when in decompression. At this depth, or below, you must perform all stops

The ceiling zone is the optimum decompression stop zone. It is the zone between the minimum ceiling and 1.2 m/4 ft below the minimum ceiling

The floor is the deepest depth at which the decompression stop time will not increase. Decompression will start when you pass this depth during your ascent

The decompression range is the depth range between the ceiling and floor. Within this range, decompression takes place. However, it is important to remember that the decompression will be very slow at, or close to, the floor

The depth of the ceiling and floor will depend on your dive profile. The ceiling depth will be fairly shallow when you enter the decompression mode, but if you remain at depth, it will move downward and the ascent time will increase. Likewise, the floor and ceiling may change upwards while you are decompressing.

When conditions are rough, it may be difficult to maintain a constant depth near the surface. In such cases, it is more manageable to maintain an additional distance below the ceiling, to make sure that the waves do not lift you above the ceiling. Suunto recommends that decompression takes place deeper than 4 m/13 ft, even if the indicated ceiling is shallower.

NOTE

WARNING

It will take more time and more air to decompress below the ceiling than at the ceiling.

NEVER ASCEND ABOVE THE CEILING! You must not ascend above the ceiling during your decompression. In order to avoid doing so by accident, you should stay somewhat below the ceiling.

Display below the floor

The blinking ASC TIME and an upward pointing arrow indicate that you are below the floor. You should start your ascent immediately. The ceiling depth is shown on the left side, and the minimum total ascent time on the right side, of the center window. Below is an example of a decompression dive without Deep Stops, below the floor.

30

Page 30
Image 30
Suunto None manual Ceiling, ceiling zone, floor and decompression range, Display below the floor