TANDBERG D14172.01 manual Command documents w, Example, Ethernet Configuration, ValueSpace

Models: D14172.01

1 84
Download 84 pages 8.98 Kb
Page 11
Image 11
</Ethernet>

TANDBERG Gatekeeper/Border Controller API User Guide

Example 1.10

From the XML structure below we see that the Speed element of Ethernet[1] is configured to Auto. The Speed element references the EthernetSpeed element in the ValueSpace document, showing the value domain for this configuration.

<Configuration> <Ethernet item="1">

<Speed item="1" valueSpaceRef="/ValueSpace/EthernetSpeed[@item='1']"> Auto</Speed>

</Ethernet>

</Configuration>

---

<ValueSpace>

<EthernetSpeed item="1" type="Literal"> <Value >Auto</Value>

<Value >10half</Value> <Value >10full</Value> <Value >100half</Value> <Value >100full</Value>

</EthernetSpeed>

</ValueSpace>

To change configurations, the part(s) of the document containing the configurations to be updated should be posted back to the system with the new values. Posting configuration to the system is

described in section 1.5 Introduction to TANDBERG XML API Service (TXAS).

1.4.4 Command documents (w)

Command documents contain descriptions of the supported commands for the system. A Command consists of a Command name and a set of Command parameters. The parameter elements have attributes to denote whether the parameter is optional or required, in addition to referencing the value domain for the given parameter.

Command parameters do not contain any values when read from the system.