Zones DefaultZone Calls Call [1..900]: <Integer>

Shows the index of a call in the Default Zone.

Zones DefaultZone Bandwidth Total: <String>

Shows the total bandwidth in kbps allowed in the Default Zone.

Zones DefaultZone Bandwidth PerCall: <String>

Shows the bandwidth in kbps allowed per call in the Default Zone.

Zones DefaultZone Bandwidth Used: <String>

Shows the bandwidth in kbps being used in the Default Zone.

Zones TraversalZone [1..50] [status = <Warning/Active/Failed>]

Shows the status of the connection to the traversal zone.

Zones TraversalZone [1..50] Cause: <String>

Shows an error reason for a failure to communicate with the traversal zone. Only present if the traversal zone status is Failed or Warning.

Zones TraversalZone [1..50] Name: <String>

Shows the name of the traversal zone.

Zones TraversalZone [1..50] Traversal: <Assent/H46018>

Shows the traversal type of the traversal zone.

Zones TraversalZone [1..50] AccountName: <String>

Shows the account name for the traversal zone.

Zones TraversalZone [1..50] Gatekeeper [1..6] [status = <Unknown/Active /Failed>]

Shows the status of the connection to the gatekeeper in the traversal zone.

Zones TraversalZone [1..50] Gatekeeper [1..6] Cause: <String>

Shows an error reason for a failure to communicate with the gatekeeper. Only present if the gatekeeper status is Failed.

Zones TraversalZone [1..50] Gatekeeper [1..6] Address: <String>

Shows the address for a gatekeeper in the traversal zone.

Zones TraversalZone [1..50] Gatekeeper [1..6] Port: <String>

Shows the port for a gatekeeper in the traversal zone.

Zones TraversalZone [1..50] Calls Call [1..900]: <Integer>

Shows the index of a call in the traversal zone.

Zones TraversalZone [1..50] Bandwidth Total: <String>

Shows the total bandwidth in kbps allowed in the traversal zone.