6 Appendix
123
6.5 Appendix 5

Guidelines for setting up videoconferencing rooms

The following are a set of guidelines to consider when either building a videoconferencing
room, or using an existing room for videoconferencing.
Lighting:
 Low Contrast desired for light
intensity. No dark spots.
 Intensity @ table 800 - 1400 Lux
as measured with an Incident light
meter.
 Block sunlight from entering room.
Seating Area (Table):
 Should allow all participants to see
Monitors.
 Should allow camera to see all
participants.
 Non-shiny non-patterned
preferably light grey surface (if
table used).
Walls:
 Color: Generally high contrast
color desired. Light blue is
commonly used.
 Acoustically reflective surfaces
(such as glass or concrete) should
be covered with curtains or sound
treatment.
Audio:
 Noise Floor preferred less than
44dBC.
 Reverb Time 0,3 to 0,5 sec.
Ventilation:
 Keep in mind Noise Floor.
 Velocity = Noise. Therefore keep
velocity of air low.
Room:
 Should be located away from
noise.
 Should not have windows.
 Doors should be located off
camera.
How to prepare a typical room for videoconferencing:
The diagram below shows a typical room designed to obtain the best results when using the
system.